8 -6
96622 Issue 4.0 Jan 0
&
LINE SPEED (Valid Range 1 -FFH)
ESC/&/?/EOT
ESC/&/xx/EOT
xx = Line speed
’
PRODUCT DELAY (Valid Range_l-FFH)
ESC/’/?/EOT
ESC/’/xx/EOT
xx = Product delay
(
INTERHEAD DEL4Y
(Valid Range_l-FFH)
ESC/(/?/EOT
ESC/(/xx/EOT
xx = Interhead delay used in Twinline
)
INTERCHARACTER SPACES
(Valid Range 1-9)
ESC/)/?/EOT
ESC/)/xx/EOT
xx = Number of dot time–spaces between characters
*
NUMBER OF MULTIDOTS (Valid Range 1-3)
ESC/*/?/EOT
ESC/*/xx/EOT
xx = Number of multidots
+
ACTIVE LANGUAGE
(Valid Range 0-4)
ESC/+/?/EOT
ESC/+/xx/EOT
xx = Language for alpha date codes
00 = English; 01 = Spanish; 02 = French; 03 = Italian; 04 =
Portuguese
,
DOT INTENSITY
(Valid Range 0-9)
ESC/,/?/EOT
ESC/,/xx/EOT
xx = Drive voltage
–
AIMS LEVEL(Valid Range 0-9)
ESC/–/?/EOT
ESC/–/xx/EOT
xx = AIMS INTENSITY
Note = Aims level will change after next Print cycle.