CMOS SENSOR
GENERAL
(See manual 44-0283 CMOS Sensor for more)
SHERLOCK
CERAMIC METAL OXIDE SEMICONDUCTOR (CMOS)
REFRIGERANT GAS SENSOR was designed to detect for
the presence of a refrigerant gas within an enclosed space.
The sensor is mounted within the space to be monitored and
connected by cable to the monitoring device. Each sensor is
calibrated to a clean air base zero level at the factory prior to
shipment. There are three models of the CMOS sensor, one for
CFC/HCFC gases, one for HFC gases and one for Ammonia.
The CMOS Sensor should be utilized as a signal source for a
SHERLOCK
Refrigerant Gas Monitoring System.
APPLICATIONS
Typical applications include:
Refrigerated Rooms
HVAC Chiller Equipment Rooms
Wineries
Refrigeration Mechanical Rooms
Bakeries
Food Processing Plants
SPECIFICATIONS
ENCLOSURE RATING
Standard
NEMA1
Optional NEMA 3R
DIMENSIONS
Inches (mm)
NEMA 1
4.3 x 2.4 x 1.2(109 x 61 x 31)
NEMA 3R
7.3 x 5.9 x 6.5(186 x 151 x 166)
POWER INPUT
12VDC, 250 mAMPs
OUTPUT
0.5 - 5 VDC
(Genesis Control Only)
EFFECTIVE RANGE
20 to 1000 ppm, Control and
Refrigerant Gas Type
Dependent
ACCURACY
+- 10% to 50% of reading
(Gas Dependent, Could be
higher for some newer blends)
REPEATABILITY
±10% when proper calibration
and Maintenance is followed.
AVAILABLE GAS SENSORS
CFC/HCFC, HFC & Ammonia
OPERATING ENVIRONMENT
TEMPERATURE
-25 to 120° F (-32 to 49°C)
HUMIDITY
0 TO 85% RH Non-Condensing
CALIBRATON
Every 6 Months
WARM-UP TIME
Reading will stabilize after 3
hours. Overnight, (up to 18 Hrs)
for low temperature applications
LIFE EXPECTANCY
3 to 5 years in most applications
NOTE: These sensors, due to their nature, are susceptible
to detection of non-refrigerant gases and cannot distinguish
the presence of different refrigerant gases, only that there is
a gas present. The CMOS sensor will detect concentrations
of gasoline, diesel, and propane exhaust and fumes from
solvents, paints, cleansers, and others (Please call Genesis
Customer Support for more information.) The stated
accuarcy is a best case and some refrigerant blends can be
off as much as 100% of the Sherlock Control ppm reading.
NOTE: The stated life expectancy for this sensor is 3 to
5 years, however, continued exposure to refrigerants and
other gases and humidity and other adverse conditions can
severely decrease sensor life.
CMOS SENSOR SELECTION CHART
Model 82-0100 NEMA 1 -- CFC/HCFC gases
Model 60-0113 NEMA 3R-- CFC/HCFC gases
Model 82-0101 NEMA 1 -- HFC gases
Model 60-0128 NEMA 3R-- HFC gases
Model 82-0102 NEMA 1 -- Ammonia gas
Model 60-0129 NEMA 3R-- Ammonia gas
R-717
R-11
R-12
R-13
R-22
R-32
R-113
R-124
R-142B
R-400(Lintern)
R-402A(Hp80)
R-402B(Hp81)
R-403A(R-69S)
R-403B(R-69L)
R-405A(G2015)
R-406A(CHG)
R-409A(FX56)
R-411A(G2108A)
R-411B(G2108B)
R-412A(TP5R)
R-500(AZ50)
R-502
R-508A(Klea5R3)
R-509A(TP5R2)
R-23
R-123
R-125
R-134A
R-143A
R-152A
R-401A(Mp89)
R-401B(Mp66)
R-401C(MP62)
R-404A(HP62)
R-407A(Klea60)
R-407B(Klea61)
R-407C(9000)
R-407D(Klea)
R-408A(FX10)
R-410A(AZ20)
R-410B(9100)
R-413A
R-503
R-507A(AZ50)
R-508B(SUVA95)
Summary of Contents for SHERLOCK 102
Page 3: ...44 00 0297 SHERLOCK102 202 REV 4 1 05 02 15 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 11: ...44 00 0297 SHERLOCK102 202 REV 4 1 05 02 15 12 IR SENSOR ...
Page 49: ...44 00 0297 SHERLOCK102 202 REV 4 1 05 02 15 50 PAGE FOR FIELD WIRING SHERLOCK SYSTEM ...
Page 51: ...44 00 0297 SHERLOCK102 202 REV 4 1 05 02 15 52 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 53: ......