59
Genesis LXP
®
© 2015 Genesis Attachments, LLC
HYDRAULIC/ROTATION MAINTENANCE
Gear Pump Rotation
Setting the crossover reliefs:
1. Install a pressure gauge on the unloading valve, unplug the wires to the directional valve, and
energize the valve on the unloading valve.
2. Adjust the unloading valve to 2500 PSI.
3. Reconnect the wires to the directional valve.
4. Plug hoses at motor or secure the processor from rotating.
5. Press the switch to rotate left or right.
6. Adjust the corresponding relief valve to the pressure specified in the table.
7. Repeat for the other direction.
8. Set the unloading valve before operating.
Setting the unloading valve:
1. Install a pressure gauge on the unloading valve, unplug the wires to the directional valve and
press the switch to rotate left or right.
2. Adjust the unloading valve to the pressure specified in the table.
3. Plug the wires back into the directional valve.
ROTATION CIRCUIT
Relief Valve
Relief Valve Test Port
Flow Control Valve
Counterbalance Valve
Crossport Relief Assembly
Control Valve Gear Pump
T
A
B
P
A
B
Reservoir