56 Genesis LXP
®
© 2015 Genesis Attachments, LLC
HYDRAULIC/ROTATION
MAINTENANCE
PLANETARY GEARBOX LUBRICATION
Proper lubrication is critical to ensure performance and
long life of the gearbox. Change gearbox lubricant after
the initial 50 hours of operation. Check gearbox lubricant
every 250 hours. See table for recommended grades and
lubricant change-out schedule based on climate.
Low Temp.
Grade
Change
5˚F
(-15˚C)
SAE 80W-90W 500 hours or
annually
-50˚F
(-45˚C)
Synthetic ISO
150
1000 hours or
two years
Position processor so gearbox is level (horizontal) at a
convenient working height.
Remove rotator access cover and place an oil drain pan
under gearbox drain plug.
Remove bottom drain plug and top fill plug.
Once drained, replace bottom drain plug.
Add 32 ounces (950ml) of gearbox lubricant through fill
plug. Do not overfill.
Replace fill and inspection plugs. Reinstall access cover.
Properly dispose of used lubricant.
Gearbox Lube Change-out Procedure
Models LXP400-500 only