background image

INDEX 

page 

LGHW-3020 Hard Wired PIR Detector Installation Handbook 

 

 

Page 1. 

Introduction. 

Mounting and avoiding false alarms. 

Lens pattern. 

Wiring and Switch settings. 

Switches 

 

 

Introduction 

 

The LGHW3020  hard wired Passive Infra Red Detector (PIR) has been designed to 
meet the newest and most demanding requirements of the CCTV market.   These detec-
tors provide versatility and surpass the requirements needed for a BS8418 system. 
 
Inside the PIR is a powerful microprocessor which uses logic to determine the validity of 
an activation.   With this technology  nuisance alarms are greatly reduced. 
In addition, there are two pyro sensors which split the zones and can be gated either as 
(A + B) or (A or B) 
 
The PIR also contains a shock sensor to detect physical attack and a three axis sensor to 
detect unauthorised re-orientation and removal from the wall.   IR transmission detects 
masking (cloak) and a light and thermal sensor allow the detector to compensate for the 
outdoor environment.    
Operating voltage is 12 Volts DC. 

Summary of Contents for LGHW-3020

Page 1: ...Wired Hard Wired PIR Detector PIR Detector Installation Installation Handbook Handbook 2a BELLEVUE ROAD FRIERN BARNET LONDON N11 3ER Tel 0044 0 208 368 7887 Fax 0044 0 208 368 3952 Type LGHW 3020 Iss...

Page 2: ...orms the safest transport container in the event that a unit has to be returned for any reason Servicing This unit should not require general servicing Any repair work should only be under taken by qu...

Page 3: ...needed for a BS8418 system Inside the PIR is a powerful microprocessor which uses logic to determine the validity of an activation With this technology nuisance alarms are greatly reduced In addition...

Page 4: ...of the detector must be solid and not sway Avoid situations where the detector can over shoot the detection area Undo the two socket screws from the wall plate and remove the black fixing bracket For...

Page 5: ...s which splits each zone in two These A and B zones can be used to increase the immunity from false activations by using AND gating IE A must be followed by B within a short time period This helps red...

Page 6: ...select how long the contacts stay changed for and switches 7 8 set the number of pulses that the detector needs to count before activating the alarm relay Typically the contacts are both N C and set t...

Page 7: ...t calibration Restore factory default Alarm N C Tamper N C Alarm N O Tamper N C Alarm N C Tamper N O Relay activity 2 seconds Relay activity 5 seconds Relay activity 10 seconds Switches 1 2 3 4 5 6 7...

Page 8: ...y unit with end of line resistor LGRU16ELR 3 versions Relay module with end of line resistor LGRM8ELR 3 versions Optional antenna AE434 Transmitter module LGTX434 Portable KeyPoint LGKP Static KeyPoin...

Reviews: