LGHW-3020 Hard Wired PIR Detector Installation Handbook 

 

 

Page 2. 

Mounting. 

The correct height for the PIR is 2.5 metres above the ground however it can be mounted 
up to 4 metres but must be angled down.   Careful consideration when positioning the 
detector will greatly reduce nuisance alarms. 
The detector requires a clear view of the area to be covered.    
Make sure that nothing can move or flutter in front of the detector and avoid facing  
reflective surfaces.   The fixing of the detector must be solid and not sway.    
Avoid situations where the detector can over shoot the detection area.    
Undo the two socket screws from the wall plate and remove the black fixing bracket.    
For WALL MOUNTING use the four screws and wall plugs provided. 
For POST MOUNTING use banding or Jubilee clips.   When it is secure, the wall plate 
may be hung back on the bracket and the two socket screws re-fitted. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Avoid facing foliage such as trees that can move in the wind. 
 
 
 
 
 

 
 
 

 

 

Do not aim the detector at reflective surfaces such as 

 

cars and windows. 

 

 

2.5m  
To  
4m 

Mounting height 

    Fixing Bracket 

Screw holes X 4 

Alternative banding 
or jubilee clip. 
The buckle can go 
on the inside 

Summary of Contents for LGHW-3020

Page 1: ...Wired Hard Wired PIR Detector PIR Detector Installation Installation Handbook Handbook 2a BELLEVUE ROAD FRIERN BARNET LONDON N11 3ER Tel 0044 0 208 368 7887 Fax 0044 0 208 368 3952 Type LGHW 3020 Iss...

Page 2: ...orms the safest transport container in the event that a unit has to be returned for any reason Servicing This unit should not require general servicing Any repair work should only be under taken by qu...

Page 3: ...needed for a BS8418 system Inside the PIR is a powerful microprocessor which uses logic to determine the validity of an activation With this technology nuisance alarms are greatly reduced In addition...

Page 4: ...of the detector must be solid and not sway Avoid situations where the detector can over shoot the detection area Undo the two socket screws from the wall plate and remove the black fixing bracket For...

Page 5: ...s which splits each zone in two These A and B zones can be used to increase the immunity from false activations by using AND gating IE A must be followed by B within a short time period This helps red...

Page 6: ...select how long the contacts stay changed for and switches 7 8 set the number of pulses that the detector needs to count before activating the alarm relay Typically the contacts are both N C and set t...

Page 7: ...t calibration Restore factory default Alarm N C Tamper N C Alarm N O Tamper N C Alarm N C Tamper N O Relay activity 2 seconds Relay activity 5 seconds Relay activity 10 seconds Switches 1 2 3 4 5 6 7...

Page 8: ...y unit with end of line resistor LGRU16ELR 3 versions Relay module with end of line resistor LGRM8ELR 3 versions Optional antenna AE434 Transmitter module LGTX434 Portable KeyPoint LGKP Static KeyPoin...

Reviews: