18
1
φ
AC
Line Input
Ground
(Earth)
L1
L2
T1
T2
T3
3
φ
AC
Induction Motor
FIGURE 3A – POWER CONNECTIONS for PKG. A and PKG. C
MODELS with 1
φ
AC LINE INPUT
P
R
L2
L1(L)
L3(N)
T1
T2
T3
3
φ
AC
Induction Motor
Optional
Brake Resistor
*For 1
φ
AC line input, use Terminals L1(L) and L3(N)
3
φ
AC*
Line Input
Ground
(Earth)
FIGURE 3B – POWER CONNECTIONS for PKG. B
MODELS with 1
φ
and
3
φ
AC LINE INPUT
FIGURE 3C – POWER CONNECTIONS for PKG. C1
MODELS (NEMA-4) with 1
φ
and
3
φ
AC LINE INPUT
Brake Resistor
Optional
3
φ
AC
Induction Motor
*For 1
φ
AC Line Input,
use Terminals L1(L) and L2(N)
AC Line Input*
T1
T2
P
T3
R
Chassis
(Earth)
Ground
Chassis
230VAC Models
460VAC Models
L3
L1(L) L2(N)
L1
L2
L3
TM3
TM1