c. Automatic Restart for All Faults Including AC Power Loss* –
If the
application requires that the drive automatically restart after a fault has
cleared, including an AC power loss, Function F28 must be set as fol-
lows. See Table 14.
To change the setting of F28 from “001” to “000”:
1. The drive must be in Stop Mode (press the RUN/STOP key).
2. Press the DSP/FUN key to display function number.
3. Press the
▲
or
▼
/RESET key until “F28” is displayed.
4. Press the DATA/ENT key. The function code will be displayed.
Factory setting is “001” [Disable Automatic AC Line Start].
5. Press the
▲
or
▼
/RESET key until code “000” is displayed.
6. Press DSP/FUN key to return to the frequency display or press the
▲
or
▼
/RESET key to change to another function number.
*
Note: For Automatic Restart, Function F10 must be set to
“001” [External Contacts] and a jumper must be installed
between Terminals 3 and 5 of Terminal Block TM2.
Function
Number
Function Description
Code/Value
Description of Code/Value
F23
Auto Restart After a Fault
Has Cleared
000
(Factory Setting)
Enable Auto Restart After a
Fault Has Cleared
F24
Number of Auto Restart
Attempts
005
(Factory Setting is “000”)
Five Auto Restart Attempts
F28
Automatic AC Line Start
000
(Factory Setting is “001”)
Enable Automatic AC Line Start
F10
Start/Stop Control
001
(Factory Setting is “000”)
External Contacts
(Jumper Terms. 3 & 5 of TM2)
TABLE 14 – FUNCTIONS F23, F24, F28 SET FOR AUTOMATIC RESTART
FOR ALL FAULTS INCLUDING AC POWER LOSS
4. F11 (Frequency Control Method) –
Frequency Control Method is used to
set the drive for either keypad, potentiometer, voltage following, or current
following frequency control, as described in Section IX, on page 42. F11 is
factory set to “000” [Keypad] to control output frequency with the keypad.
Note:
1. SW1 must also be set to the proper setting for voltage or current
signal input, as described in Section V-B-1, on page 21.
To change the setting of F11 from “000” [Keypad] to “001”
[External Contacts]:
a. The drive must be in Stop Mode (Press the RUN/STOP key).
34
Sec. VIII – Drive Operation (Cont.)
Summary of Contents for KBE2
Page 55: ...55 NOTES...