Symptom
Possible Causes
Possible Solutions
Tines lack clamping
power
Excavator is not putting out full pressure to
the tine circuit
Check excavator circuit relief valve
Cross-over relief valve setting is too low
Adjust the cross-over relief valves
Tine cylinder(s) is bypassing internally
Replace cylinder seals
Swivel is bypassing internally
Replace swivel seals
Tines drift closed
Swivel is bypassing internally
Replace swivel seals
Tine cylinder(s) is bypassing internally
Replace cylinder seals
Tine closing and
opening speed is
slow
Flow from excavator is too slow
Check excavator hydraulic system flow
Swivel is bypassing
Replace swivel seals
Tine cylinder(s) is bypassing internally
Replace or reseal the cylinder(s)
Grapple rotation is
weak
Low supply pressure from the excavator Check rotation pressure, adjust or replace
the relief valve
Hydraulic motor is worn
Replace hydraulic motor
Grapple rotation is
slow
Flow from excavator is too slow
Check excavator hydraulic system flow
Worn hydraulic motor
Replace the hydraulic motor
TROUBLE-SHOOTING GUIDE