Model IR400 HART
14
Code
Class
Description
6 - 127
Undefined
Command #152: Read Run Time Meter
This reads the internal run time meter.
Request Data Bytes
Byte
Format
Description
0 N/A
N/A
Response Data Bytes
Byte
Format
Description
0 - 3
Unsigned-32
Run Time Meter Value
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1-127
Undefined
Command #154: Set Event Index
This sets the index of logged event to read. 0 – latest event
Request Data Bytes
Byte
Format
Description
0
Unsigned - 8
Sets index of logged event to read using commands 143 – 146.
Range 0 – 9.
Response Data Bytes
Byte
Format
Description
0
Unsigned - 8
Event Index
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1 - 2
Undefined
3
Error
Passed Parameter Too Large
4
Undefined
5
Error
Too Few Data Bytes Received
6 - 127
Undefined