Xedge Chassis Systems
Xedge 6640/6645 Chassis
2-40
Xedge 6000 Hardware
032R440-000
Installation & Setup Guide
Issue 17
Xedge 6640/6645 System Management Connections
The two DB-25 connectors (MANAGER) at the chassis rear panel provide local management
access to the Slot-0 Main and Slot-0 Standby controllers via an asynchronous terminal for local
configuration and management of the switch.
lists the pinouts for this management port.
Note
The Craft Port Security Key must be in the ON position to enable craft access to the slot-0 controller.
1. Depending on which slot-0 controller is in use, connect the terminal to the associated female
DB-25 MANAGER connector (main or standby).
2. Set the terminal to the following parameters:
•
VT100 emulation
•
19,200 baud
•
8 character bits
•
No parity
•
No flow control
•
Data Terminal Ready (DTR, pin 20) high from terminal.
Note
The initial model of the Xedge PCL(1) slot controller is intended for operation only in the Xedge 6002 chassis
with the local management terminal set to 9600 baud. A later model of the Xedge PCL(2) is intended for
nonslot-0 use in any Xedge chassis with the terminal set to 19,200 baud.
Table 2-11
Xedge 6640/6645 Craft Port Pinouts
Pin
Signal
1
GND
2
TXD
3
RXD
4
--
5
--
6
DSR
7
GND
8
--
9
--
10
--
11
--
12
--
13
--
14
--
15
--
16
--
17
--
18
--
19
--
20
DTR
21
--
22
--
23
--
24
--
25
--