System Operation
Installation and Owner’s Manual for Generac PWRCell Inverter
43
Section 7: System Operation
General Information
The PWRcell system is a flexible, highly customizable
system that can be configured in a number of ways to
meet customer needs. Correct system configuration
requires selecting the right equipment and the correct
system mode for the system.
All REbus devices are configured and controlled through
the Generac PWRcell Inverter. Connected devices will
appear on the LCD display.
Operation and User Interface
See
. Generac PWRcell is controlled through
the PWRcell Inverter control panel. The inverter control
panel is used for adjusting system settings and for
interacting with devices.
•
Use left and right arrows (A) to navigate between
pages.
Press center button (B) on a device page to select or
deselect device settings.
Figure 7-1. Inverter Control Panel
Home Screen
See
. The power flow display on the home
screen illustrates the flow of power in the system. As
power is generated, stored, and consumed, animated
arrows indicate the flow and direction of power. System
AC and DC voltage levels are displayed near the center
of the screen. The current system mode is displayed at
the top of the screen.
Figure 7-2. Home Screen
Home Screen Icons
REbus
Inverter
Internet
Shutdown
(hold)
009894
B
A
Represents the PWRcell Inverter.
Represents the cumulative production of the solar
array connected to PV Links.
Represents PWRcell Batteries, if installed.
Represents house loads including backup loads
or AC Coupled AV if installed.
Represents the Utility Grid when CTs are suc
-
cessfully calibrated. This icon will not appear on
the home screen if CTs are not calibrated.
012920