Generac Power Systems 0065141C Owner'S Manual Download Page 10

  8 

2.4.3   CONNECTING THE GENERATOR TO A BUILDING’S 

ELECTRICAL SYSTEM

When connecting directly to a building's electrical system, it is recommended 
that a manual transfer switch is used. Connections for a portable generator to 
a building's electrical system must be made by a qualified electrician and in 
strict compliance with all national and local electrical codes and laws.

Figure 8 - Grounding the Generator

2.5 

DON’T OVERLOAD THE GENERATOR

Overloading a generator in excess of its rated wattage capacity can 
result in damage to the generator and to connected electrical devices. 
Observe the following to prevent overloading the unit:

•  Add up the total wattage of all electrical devices to be connected 

at one time. This total should NOT be greater than the generator's 
wattage capacity.

•  The rated wattage of lights can be taken from light bulbs. The rated 

wattage of tools, appliances and motors can usually be found on 
a data label or decal affixed to the device.

•  If the appliance, tool or motor does not give wattage, multiply volts 

times ampere rating to determine watts (volts x amps = watts).

•  Some electric motors, such as induction types, require about three 

times more watts of power for starting than for running. This surge 
of  power  lasts  only  a  few  seconds  when  starting  such  motors. 
Make  sure  to  allow  for  high  starting  wattage  when  selecting 
electrical devices to connect to the generator:

1.  Figure the watts needed to start the largest motor.
2.  Add to that figure the running watts of all other connected loads.

The  Wattage  Reference  Guide  is  provided  to  assist  in  determining 
how many items the generator can operate at one time.

NOTE:

All  figures  are  approximate.  See  data  label  on  appliance  for 
wattage requirements.

2.6 

WATTAGE REFERENCE GUIDE

  Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Running Watts

  *Air Conditioner (12,000 Btu)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1700
  *Air Conditioner (24,000 Btu)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3800
  *Air Conditioner (40,000 Btu)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6000
  Battery Charger (20 Amp). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
  Belt Sander (3")  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
  Chain Saw. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  Circular Saw (6-1/2"). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800 to 1000
  *Clothes Dryer (Electric)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5750
  *Clothes Dryer (Gas). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
  *Clothes Washer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1150
  Coffee Maker. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1750
  *Compressor (1 HP)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
  *Compressor (3/4 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800
  *Compressor (1/2 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1400
  Curling Iron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
  *Dehumidifier. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 650
  Disc Sander (9")  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  Edge Trimmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
  Electric Blanket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
  Electric Nail Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  Electric Range (per element)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
  Electric Skillet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1250
  *Freezer . . . . . . .  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..700
  *Furnace Fan (3/5 HP)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 875
  *Garage Door Opener. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .500 to 750
  Hair Dryer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  Hand Drill  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 to 1100
  Hedge Trimmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450
  Impact Wrench  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
  Iron  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  *Jet Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800
  Lawn Mower  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  Light Bulb  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
  Microwave Oven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .700 to 1000
  *Milk Cooler. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1100
  Oil Burner on Furnace  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
  Oil Fired Space Heater (140,000 Btu)  . . . . . . . . . . . . . . . . . . . . . . . . 400
  Oil Fired Space Heater (85,000 Btu)  . . . . . . . . . . . . . . . . . . . . . . . . . 225
  Oil Fired Space Heater (30,000 Btu)  . . . . . . . . . . . . . . . . . . . . . . . . . 150
  *Paint Sprayer, Airless (1/3 HP)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600
  Paint Sprayer, Airless (handheld) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
  Radio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 to 200
  *Refrigerator  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
  Slow Cooker  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
  *Submersible Pump (1-1/2 HP)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2800
  *Submersible Pump (1 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
  *Submersible Pump (1/2 HP)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
  *Sump Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800 to 1050
  *Table Saw (10") . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1750 to 2000
  Television  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200 to 500
  Toaster  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000 to 1650
  Weed Trimmer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
  * Allow 3 times the listed watts for starting these devices.

Operation

Summary of Contents for 0065141C

Page 1: ...r www generac com or 1 888 436 3722 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS SAVE this Manual Provide this...

Page 2: ...nits Only 11 Maintenance 11 3 1 Performing Scheduled Maintenance 11 3 2 Maintenance Schedule 11 3 3 Product Specifications 11 3 4 General Recommendations 12 3 5 Service Air Filter 13 3 6 Valve Clearan...

Page 3: ...g technique that the manufacturer does not specifically recommend ensure that it is safe for others Also make sure the procedure work method or operating technique utilized does not render the generat...

Page 4: ...tical to correct generator operation Do not alter the installation or permit even partial blockage of ventilation provisions as this can seriously affect safe operation of the generator The generator...

Page 5: ...ntilation of the generator Do not insert objects through unit s cooling slots Never operate the generator if connected electrical devices overheat if electrical output is lost if engine or generator s...

Page 6: ...Refer to Figure 1 and install the Frame Foot and Rubber Bumpers as shown Slide the Rubber Bumper studs through the Frame Foot then install the Locking Flange Nuts Slide the Hex Head Bolts through the...

Page 7: ...Amp single phase 60 Hz electrical lighting appliance tool and motor loads 3 Circuit Breakers AC Each receptacle is provided with a push to reset circuit breaker to protect the generator against elect...

Page 8: ...off when the engine is running This signifies that the meter is tracking hours of operation 2 3 CONNECTION PLUGS 2 3 1 120 VAC 20 AMP GFCI DUPLEX RECEPTACLE This is a 120 Volt outlet protected agains...

Page 9: ...n of the generator The generator MUST be operated outdoors This exhaust system must be properly maintained Do nothing that might render the exhaust system unsafe or in noncompliance with any local cod...

Page 10: ...rt the largest motor 2 Add to that figure the running watts of all other connected loads The Wattage Reference Guide is provided to assist in determining how many items the generator can operate at on...

Page 11: ...g open flames sparks or heat in the vicinity while handling gasoline 1 Use regular UNLEADED gasoline with the generator engine Do not use any gasoline with more than 10 added ethanol Do not use E85 ga...

Page 12: ...in to the Run position If engine falters move choke knob back out to 1 2 Choke position until the engine runs smoothly and then to Run position 2 9 1 MANUAL START This generator is also equipped with...

Page 13: ...er input is protected by a 1 5 Amp replaceable in line fuse Figure 12 Battery Charger Jack BATTERY CHARGER INPUT 3 1 PERFORMING SCHEDULED MAINTENANCE It is important to perform service as specified in...

Page 14: ...on the generator internal windings will eventually decrease the insulation resistance of these windings 3 4 2 TO CLEAN THE GENERATOR Use a damp cloth to wipe exterior surfaces clean A soft bristle br...

Page 15: ...before re installing it NOTE To order a new air filter please contact the nearest authorized service center at 1 888 436 3722 Figure 15 Air Filter KNOB TO OPEN AIR BOX 3 6 VALVE CLEARANCE Intake 0 15...

Page 16: ...e the unit in a clean dry place 3 9 OTHER STORAGE TIPS Do not store gasoline from one season to another Replace the gasoline can if it starts to rust Rust and or dirt in the gasoline will cause proble...

Page 17: ...Low oil level 10 Excessive rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Turn Fuel Shut off ON 2 Clean or replace air filter 3 Fill fuel tank 4 Drain fuel tan...

Page 18: ...MENT SERVICE PARTS Description Part No Oil Quart 0G0752 Spark Plug 0G84420101 Air Filter 0G84420151 Fuel Filter 0H1326 Battery 0G9449 Battery Fuse 0K3029 Spark Arrestor 0K3857 Maintenance Kit 005577 0...

Page 19: ...17 Notes...

Page 20: ...10 07 14 Printed in U S A 2014 Generac Power Systems Inc All rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from...

Page 21: ...m o 1 888 436 3722 PELIGRO EMANACIONES DE ESCAPE MORTALES Use NICAMENTE EN EXTERIORES lejos de ventanas puertas y ventilaciones NO EST N DESTINADOS AL USO EN APLICACIONES CR TICAS DE SOPORTE A LA VIDA...

Page 22: ...uci n del mantenimiento programado 11 3 2 Programa de mantenimiento 11 3 3 Especificaciones del producto 11 3 4 Recomendaciones generales 12 3 5 Servicio del filtro de aire 13 3 6 Luz de v lvulas 13 3...

Page 23: ...cnica de funcionamiento que el fabricante no recomienda espec ficamente aseg rese de que sea seguro para otras personas Aseg rese tambi n de que el procedimiento m todo de trabajo o t cnica de funcio...

Page 24: ...ciones suficientes puede causar inconsciencia o incluso la muerte El flujo adecuado y sin obstrucciones de aire de enfriamiento y ventilaci n resulta cr tico para el funcionamiento adecuado del genera...

Page 25: ...use el generador si los dispositivos el ctricos conectados se recalientan si se pierde la salida el ctrica si el motor o el generador producen chispas o si se observan llamas o humo mientras la unida...

Page 26: ...lte la Figura 1 e instale el pie del bastidor y los parachoques de caucho como se muestra Deslice los esp rragos de los parachoques de caucho a trav s del pie del bastidor e instale las contratuercas...

Page 27: ...30 A monof sicos de 60 Hz 3 Disyuntores CA Cada tomacorriente cuenta con un disyuntor de pulsar para reconectar para proteger al generador contra sobrecargas el ctricas 4 Vaciado de aceite Se usa para...

Page 28: ...llevando un registro de las horas de funcionamiento 2 3 ENCHUFES DE CONEXI N 2 3 1 TOMACORRIENTE DOBLE DE 120 VCA 20 A GFCI Es un tomacorriente de 120 V protegido contra sobrecargas por un disyuntor...

Page 29: ...er inseguro al sistema de escape o que infrinja cualquier c digo y o norma local Siempre use en interiores una alarma de mon xido de carbono alimentada por bater a instalada conforme a las instruccion...

Page 30: ...ios de consumo funcionando de todas las otras cargas conectadas La gu a de referencia de potencia en vatios se provee para asistir en la determinaci n de cu ntos elementos puede accionar el generador...

Page 31: ...que se fume o que haya llamas abiertas chispas o calor en la zona mientras maneje gasolina 1 Use gasolina com n SIN PLOMO en el motor del generador No use ninguna gasolina con m s de 10 de etanol a a...

Page 32: ...y luego a la posici n de funcionamiento Si el motor falla intermitentemente tire de la perilla del cebador nuevamente a la posici n de medio cebado hasta que el motor funcione suavemente y luego a la...

Page 33: ...1 5 A sustituible Figura 12 Conector del cargador de bater a BATER A ENTRADA DEL CARGADOR 3 1 EJECUCI N DEL MANTENIMIENTO PROGRAMADO Es importante ejecutar el mantenimiento como se indica en el Progra...

Page 34: ...el aislamiento de estos devanados 3 4 2 LIMPIEZA DEL GENERADOR Use un pa o h medo para limpiar las superficies exteriores Se puede usar un cepillo de cerdas suave para aflojar tierra compactada aceite...

Page 35: ...es de volver a instalarla NOTA Para pedir un filtro de aire nuevo comun quese con el centro de servicio autorizado m s cercano llamando al 1 888 436 3722 Figura 15 Filtro de aire PERILLA PARAABRIR LA...

Page 36: ...cuentren abiertas y sin obstrucciones 8 Almacene la unidad en un lugar limpio y seco 3 9 OTROS CONSEJOS SOBRE EL ALMACENAMIENTO No almacene gasolina de una estaci n a otra Sustituya el contenedor de g...

Page 37: ...de admisi n se encuentra atorada abierta o cerrada 12 El motor ha perdido compresi n 1 Gire la v lvula de cierre de combustible a la posici n ON 2 Limpie o sustituya el filtro de aire 3 Llene el tanq...

Page 38: ...cripci n N m de pieza Aceite cuarto de gal 0G0752 Buj a 0G84420101 Filtro de aire 0G84420151 Filtro de combustible 0H1326 Bater a 0G9449 Fusible de bater a 0K3029 Supresor de chispas 0K3857 Kit de man...

Page 39: ...17 Notas Notas...

Page 40: ...Impreso en EE UU 2014 Generac Power Systems Inc Todos los derechos reservados Las especificaciones est n sujetas a cambios sin aviso No se permite la reproducci n bajo ninguna forma sin previo consen...

Reviews: