![Generac Mobile Products MLT6SK Operating Manual Download Page 26](http://html.mh-extra.com/html/generac-mobile-products/mlt6sk/mlt6sk_operating-manual_2208816026.webp)
Operation
20
MLT6SM/K-8SK Operating Manual
17973 G
4. Rotate the mast by loosening the mast rotation knob at the bottom of the mast (D). Turn the mast until the
lights face in the desired direction and then tighten the mast rotation knob to secure the mast in position.
WARNING
Never raise or lower the mast while the unit is operating.
STARTING THE UNIT
Note: If the engine was run out of fuel or the fuel tank was drained, it may be necessary
to bleed the fuel lines. Refer to the engine operator’s manual supplied with the unit.
5. Check that the main circuit breaker(s) are in the OFF (O) position.
6. Turn the key on the Control Power switch to the right Glow Plug (
) posi-
tion and hold the key in place for five seconds, then turn the key to the right
Start (
) position and hold it until the engine cranks and starts running.
Release the key, it will move to the Run (
) position.
Figure 10 - Direction of
Switches
Note: For cold weather conditions, refer to the engine operator’s manual for appropriate glow plug interval.
Figure 11 - Key Locations to Starting the Unit
Do not crank the engine longer than 10 seconds at a time. If the engine will not start, wait
30 seconds to allow the starter motor to cool and then repeat the starting procedure.
Excessive cranking will cause damage to the starter.
Note: If oil pressure is not obtained within 15 seconds after the key is switched to the Run (
) position, the low oil
automatic shutdown will turn off the fuel supply, stopping the engine. Check the oil level and turn the key to the Stop
(
) position to reset the oil pressure timer before attempting to restart the engine.
7. Once the engine is running, allow it to reach normal operating temperature before switching on any loads.
LIGHT OPERATION
WARNING
NEVER operate the lights without the protective lens cover, or with a lens cover that
is cracked or damaged. The bulbs in the light fixtures produce high temperatures and
operate under pressure. A broken or missing lens cover could cause the bulbs to
shatter, causing injury.
00759
I
O
I
O
I
O
I
O
MAIN
BREAKER
240V
I
O
I
O
00760
CRANK ENGINE TO START
STOP
15 SEC.
MAX.
RELEASE KEY
STOP
15 SEC.
MAX.
ACTIVATE GLOW PLUGS
STOP
15 SEC.
MAX.
STOP
Summary of Contents for MLT6SK
Page 4: ...iv This Page Intentionally Left Blank ...
Page 12: ...Safety 6 MLT6SM K 8SK Operating Manual 17973 G This Page Intentionally Left Blank ...
Page 32: ...Operation 26 MLT6SM K 8SK Operating Manual 17973 G This Page Intentionally Left Blank ...
Page 34: ...Maintenance 32 MLT6SM K 8SK Operating Manual 17973 G This Page Intentionally Left Blank ...
Page 36: ......