Rev. 00 09/22
UA05
Start-up
•
31
Fig. 11: Reference point and mechanical stop
1
Stop
2
Fixing screws
The position of the mechanical stop is set by a Gema service engineer
during assembly.
The reference point must be referenced before each start-up (at
each switching on, after an interruption of the power supply etc.)!
Setting of the mechanical stop
When setting of the mechanical stop the vertical axis must be
disconnected from mains!
In order to set the mechanical stop, the stop position hast to be measured
– for this reason, consider the maximum distance to the booth gun slots!
ATTENTION
An incorrect set stroke limit will lead to damage to the gun axis
and/or the booth!
► Before connecting or switching on the axis, read carefully these
operating instructions!
► See the user manual of the axis control unit!
Procedure:
1.
Switch off the power supply.
2.
Loosen the screws (
2
) and move the mechanical stop (
1
) to the
desired position
3.
Tighten the screws
Tightening torque: 5 Nm
After the adjustment of the mechanical stop, check the system
parameter for the upper stop on the axis control unit!
► The value must not be larger than the maximum stroke possible
between the stops!
Summary of Contents for UA05
Page 5: ...Rev 00 09 22 UA05 Table of contents 5 ...
Page 6: ......
Page 12: ...Rev 00 09 22 12 Safety UA05 ...
Page 14: ...Rev 00 09 22 14 Transport UA05 ...
Page 24: ...Rev 00 09 22 24 Product description UA05 ...
Page 28: ...Rev 00 09 22 28 Assembly Connection UA05 ...
Page 32: ...Rev 00 09 22 32 Start up UA05 ...
Page 34: ...Rev 00 09 22 34 Operation UA05 ...
Page 42: ...Rev 00 09 22 42 Maintenance Repairs UA05 4 5 6 ...
Page 43: ...Rev 00 09 22 UA05 Maintenance Repairs 43 7 8 9 ...
Page 54: ......
Page 56: ...Rev 00 ...