Rev. 00 03/19
OptiFlex Pro B Spray
Operation
31
Setting powder output and powder cloud
The powder output depends on the selected powder output (in %), and
the powder cloud on the selected total air volume.
The AP01 Application pump should be operated with powder at
least 1/2 hour after starting up.
– After the running-in of the filter elements a stable powder output
value will be reached.
As a factory default value, a powder rate of 60% and a total air
volume of 4 Nm³/h are recommended.
– If values are entered that the gun control unit cannot implement,
then the operator is informed of this by a blinking in the relevant
display and a temporary error message!
Setting the total air volume
1.
Adjust the total air volume on the gun control unit with the
T3/T4
keys
– Adjust the total air volume according to the corresponding coating
requests
correct powder cloud
too little total air
Setting the powder output
1.
OR