Rev. 00 03/19
30
Operation
OptiFlex Pro B Spray
Select predefined operating mode (Preset mode)
1. Turn on the gun control unit with the
ON
key
2. Press the corresponding application key.
The arrow above the desired button lights up.
The pre-defined application modes have preset values for high
voltage and spray current:
Application mode
Preset µA
Preset kV
flat parts
100
100
complicated parts
22
100
overcoat
10
100
3. The air values for total air, powder output and electrode rinsing air
can be individually defined and are saved in the programs.
Starting the individual adjustable programs
1. Turn on the gun control unit with the
ON
key
2. Press the
program key
3. Select the desired program (01-20)
Program 20 active
4. Change the coating parameters as required
Programs 01-20 are preset at the factory but can be modified at
any time, after which they are automatically stored.
Description
Presetting
Powder output
60 %
Total air
4.0 Nm³/h
High voltage
80 kV
Spray current
20 µA
Electrode rinsing air
0.1 Nm³/h
Fluidizing air
1.0 Nm³/h (for device type F)
0.1 Nm³/h (for device type B and S)
Summary of Contents for OptiFlex Pro B Spray
Page 6: ......
Page 14: ...Rev 00 03 19 14 Safety OptiFlex Pro B Spray ...
Page 22: ...Rev 00 03 19 22 Product description OptiFlex Pro B Spray ...
Page 26: ...Rev 00 03 19 26 Assembly Connection OptiFlex Pro B Spray ...
Page 48: ...Rev 00 03 19 48 Disposal OptiFlex Pro B Spray ...
Page 51: ...Rev 00 03 19 OptiFlex Pro B Spray Spare parts list 51 OptiFlex Pro B Spray Spare parts fig 10 ...
Page 56: ......
Page 58: ...Rev 00 ...