Rev. 00 03/19
46
Fault clearance
OptiFlex Pro B Spray
Incident
Causes
Corrective action
Solenoid valve in the control
unit defective
Replace
No conveying air:
– Throttle motor defective
– Solenoid valve defective
Contact local Gema
representative
Front plate defective
Contact local Gema
representative
Gun achieving only poor
spray profile
Total air incorrectly configured
Increase the powder quantity
and/or total air volume on the
control unit
Bend or damage to air lines to
application pump
Check air lines to application
pump
Pinch valve hose in the
application pump worn
Replace
Fluidization not running
see below
No electrode rinsing air
Rinsing air throttle motor
defective
Contact local Gema
representative
The powder is not fluidized
Compressed air not present
Connect the equipment to the
compressed air
Fluidizing air is set too low on
the control unit
Adjust the fluidization correctly
Throttle motor defective
Contact local Gema
representative
Vibrator not functioning
Vibrator/condenser broken
Contact local Gema
representative
Vibrator not plugged in
plug in
Incorrect equipment type
configured
Configure parameter P00 (See
operating instructions for the
manual gun control unit,
Chapter "Start-up – Setting
Equipment Type")
Summary of Contents for OptiFlex Pro B Spray
Page 6: ......
Page 14: ...Rev 00 03 19 14 Safety OptiFlex Pro B Spray ...
Page 22: ...Rev 00 03 19 22 Product description OptiFlex Pro B Spray ...
Page 26: ...Rev 00 03 19 26 Assembly Connection OptiFlex Pro B Spray ...
Page 48: ...Rev 00 03 19 48 Disposal OptiFlex Pro B Spray ...
Page 51: ...Rev 00 03 19 OptiFlex Pro B Spray Spare parts list 51 OptiFlex Pro B Spray Spare parts fig 10 ...
Page 56: ......
Page 58: ...Rev 00 ...