Rev. 00 09/16
OptiFlex 2 F
OptiSelect GM03
51
Various adapters for connection to earlier generations of control
units
Gloves, anti-static
**for more information, see spare parts list
Technical Data
Electrical data
OptiSelect GM03
Nominal input voltage
eff. 10 V
Frequency
18 kHz (average)
Nominal output voltage
100 kV
Polarity
negative (optional
positive)
Max. output current
100 µA
High voltage display
with LED
Ignition protection
Ex 2 mJ T6
Temperature range
0 °C - +40 °C
(+32 °F - +104 °F)
Max. surface temperature
85 °C (+185 °F)
Protection type
IP64
Approvals
0102
II 2D
PTB 11 ATEX 5006
Dimensions
OptiSelect GM03
Weight
520 g
Processible powders
OptiSelect GM03
Plastic powder
yes
Metallic powder
yes
Enamel powder
no
Summary of Contents for OptiFlex 2 F
Page 12: ...Rev 00 09 16 12 Safety OptiFlex 2 F ...
Page 20: ...Rev 00 09 16 20 Assembly Connection OptiFlex 2 F ...
Page 32: ...Rev 00 09 16 32 Operation OptiFlex 2 F 29 30 ...
Page 34: ...Rev 00 09 16 34 Decommissioning Storage OptiFlex 2 F ...
Page 48: ...Rev 00 09 16 48 Fault clearance OptiFlex 2 F ...
Page 52: ...Rev 00 09 16 52 OptiSelect GM03 OptiFlex 2 F ...
Page 59: ...Rev 00 09 16 OptiFlex 2 F Maintenance Repairs 59 Replacing the insert sleeve 1 2 3 4 ...
Page 60: ...Rev 00 09 16 60 Maintenance Repairs OptiFlex 2 F ...
Page 62: ...Rev 00 09 16 62 Fault clearance OptiFlex 2 F ...
Page 65: ...Rev 00 09 16 OptiFlex 2 F Spare parts list 65 OptiFlex 2 F Spare parts fig 14 ...
Page 82: ...Rev 00 09 16 82 Spare parts list OptiFlex 2 F OptiFlow IG06 spare parts fig 24 ...
Page 84: ...Rev 00 ...