Rev. 00 09/16
10
Safety
OptiFlex 2 F
Slip hazard
Powder lying on the floor around the powder spraying equipment is a
potentially dangerous source of slipping. Booths may be entered only in
the places suitable for it.
Static charges
Static charges can have the following consequences: Charges to people,
electric shocks, sparking. Proper grounding must be in place to prevent
objects from becoming charged.
Grounding
Observe the grounding
regulations
All electrically conductive parts found in the workplace of 5 meters
around each booth opening, and particularly the objects to be coated,
have to be grounded. The grounding resistance of each object must
amount to maximally 1 MOhm. This resistance must be checked/tested
regularly when starting work.
The condition of the work piece attachments, as well as the hangers,
must guarantee that the work pieces remain grounded. The appropriate
measuring devices must be kept ready in the workplace, in order to
check the grounding.
The floor of the coating area must conduct electricity (normal concrete is
generally conductive).
The supplied grounding cable (green/yellow) must be connected to the
grounding screw of the electrostatic manual powder coating equipment.
The grounding cable must have a good metallic connection with the
coating booth, the recovery unit and the conveyor chain, respectively
with the suspension arrangement of the objects.
Smoking and open flames
Fire and smoke
prohibition
Smoking and igniting fire are forbidden in the entire vicinity of the
system! No work that could potentially produce sparks is allowed!
Stay for persons with cardiac pacemakers
The stay for persons
with cardiac pacemakers
is forbidden
As a general rule for all powder spraying installations, persons with
pacemakers should never enter high voltage areas or areas with
electromagnetic fields. Persons with pacemakers should not enter areas
with powder spraying installations!
Summary of Contents for OptiFlex 2 F
Page 12: ...Rev 00 09 16 12 Safety OptiFlex 2 F ...
Page 20: ...Rev 00 09 16 20 Assembly Connection OptiFlex 2 F ...
Page 32: ...Rev 00 09 16 32 Operation OptiFlex 2 F 29 30 ...
Page 34: ...Rev 00 09 16 34 Decommissioning Storage OptiFlex 2 F ...
Page 48: ...Rev 00 09 16 48 Fault clearance OptiFlex 2 F ...
Page 52: ...Rev 00 09 16 52 OptiSelect GM03 OptiFlex 2 F ...
Page 59: ...Rev 00 09 16 OptiFlex 2 F Maintenance Repairs 59 Replacing the insert sleeve 1 2 3 4 ...
Page 60: ...Rev 00 09 16 60 Maintenance Repairs OptiFlex 2 F ...
Page 62: ...Rev 00 09 16 62 Fault clearance OptiFlex 2 F ...
Page 65: ...Rev 00 09 16 OptiFlex 2 F Spare parts list 65 OptiFlex 2 F Spare parts fig 14 ...
Page 82: ...Rev 00 09 16 82 Spare parts list OptiFlex 2 F OptiFlow IG06 spare parts fig 24 ...
Page 84: ...Rev 00 ...