Rev. 00 09/16
36
Maintenance / Repairs
OptiFlex 2 F
If in disuse for several days
1.
Separate from power mains
2.
Clean the coating equipment
3.
Turn off the compressed air main supply
Powder hose rinsing
If longer downtimes take place, the powder hose has to be cleaned.
Procedure:
1.
Disconnect the powder hose from the hose connection on the
injector
2.
Point the gun into the booth
3.
Blow through the hose manually with a compressed air gun
4.
Connect the powder hose again to the hose connection on the
injector
Gun maintenance
The gun is designed to require only a minimum amount of maintenance.
1.
Clean the gun with dry cloth, see chapter "Maintenance"
2.
Check connection points to powder house.
3.
Replace the powder hoses, if necessary.