3 Definition of terms
Working medium
The medium that flows through the
diaphragm globe valve.
4 Intended area of use
The GEMÜ C57 HPW diaphragm
globe valve
iComLine
®
is designed for
installation in piping systems. It controls a
fl
owing medium by manual operation.
The diaphragm globe valve may
only be used providing the product
technical criteria are complied with
(
see chapter 5 "Technical data"
)
.
Do not paint the bolts and plastic parts of
the diaphragm globe valve!
WARNING
Use the diaphragm globe valve only
for the intended purpose!
®
Otherwise the manufacturer liability and
guarantee will be void.
G
Use the diaphragm globe valve only
in accordance with the operating
conditions speci
fi
ed in the contract
documentation and in the installation,
operating and maintenance
instructions.
5 Technical
data
AG = bonnet size
Information on the use of the diagram
The temperature / pressure diagram is only an orientation
aid. The data refers to water as a working medium. A
change of operating conditions or other media may result
in deviations. In case of doubt it is advisable to test the
behavior of the material under the definitive operating
conditions by means of a test installation.
Temperatures under 0 °C can affect the operating speed
negatively.
-4
14 32 50 68 86 104 122 140 158 176 194 212 230 248 266 284 302
-20
-10
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
1
2
3
4
5
6
7
15
30
45
60
75
90
105
AG 1, 2
AG 3, 4
Temperature [°C]
Temperature [°F]
Pr
essur
e [P
SI]
Pressure / temperature diagram
ENGINEERED
WORKING RANGE
Pr
essur
e [bar]
Flow direction
See arrow
Materials
Media wetted parts (body)
PFA and PTFE
Diaphragm PTFE
External operator parts
PVDF
Working medium
Corrosive, inert, gaseous and liquid media - particularly high
purity media - which have no negative impact on the physical
and chemical properties of the body and diaphragm material.
Ambient temperature
Max. 60 °C (130 °F)
Operating temperature
See temperature / pressure diagram
Operating pressure
Max. 6.0 bar applied upstream
Vacuum 400
mbar/abs*
* The life expectancy of the valve may be affected if exposed to a
greater vacuum.