6.8 Electrical data
Supply voltage:
24 V DC
Tolerance ± 10 %
Operating time:
MG 10: 2.5 s
MG 20: 3.5 s
MG 25: 4.0 s
MG 40: 4.5 s
Close tight current / rated
current:
MG 10: 0.5 A
MG 20: 1.4 A
MG 25: 1.3 A
MG 40: 2.3 A
Starting current / max-
imum current:
MG 10: approx. 2.4 A
MG 20: approx. 2.4 A
MG 25: approx. 2.4 A
MG 40: approx. 4.5 A
Standby current con-
sumption:
approx. 10 mA
6.8.1 Digital input signals
Input voltage:
max. 30 V DC
High level:
≥ 18 V DC
Low level:
≤ 5 V DC
6.8.2 Emergency power supply module
Charging current:
MG 10, MG 20, MG 25: max. 0.16 A
MG 40: 0.32 A
Charging time:
approx. 13 min
Service life:
Guide value at 25 °C ambient temperature, approx. 3 years
www.gemu-group.com
14 / 41
GEMÜ R629 eSyLite
6 Technical data