www.geith.com
3-7
OPERATION
NOTE: After operating pressure has been achieved in
the quick coupler system, all 4 buttons on the
control box will illuminate and the alarm tone
will become constant.
Figure 14
When the quick coupler sliding hook (5) is fully open,
reposition the quick coupler to the open digging position
and lower the fixed hook (6) of the quick coupler down
onto the front pin (7)
of the attachment.
NOTE: Images shown installing a bucket, the
procedure is the same for installing other
attachments.
AVOID SERIOUS INJURY OR DEATH
Keep attachment close to ground during engaging or
releasing attachment. Attachment can fall off without
warning if not FULLY ENGAGED AND LOCKED
causing death or serious injury.
Figure 15
Crowd the quick coupler around until the quick coupler
contacts the attachment rear pin and raise the
attachment off the ground while continuing to crowd the
quick coupler fully inwards
.
Figure 16
With the quick coupler crowded fully, press the LOCK
button (1)
on the control box.
NOTE: When LOCK button (1) [Figure 16] is pressed,
all lights and alarm will shut off.
Figure 17
Continue to crowd the quick coupler fully for ten seconds
or until locking clasp (2) and sliding hook (3)
are fully engaged.
Install attachment hydraulic hoses (if equipped). See
Attachment Hydraulic Hose Installation (if equipped) on
Page 3-9
Perform operational check on the quick coupler. See
Quick Coupler Operation Check on Page 3-9.
7
6
5
WARNING
1
2
3
Summary of Contents for QC100 H1
Page 1: ...GEITH QUICK COUPLER MANUAL www geith com PT No 823000088876 2 Released 05 2016 ...
Page 2: ......
Page 4: ......
Page 6: ...www geith com ...
Page 10: ...1 4 www geith com INTRODUCTION ...
Page 20: ...2 10 www geith com SAFETY ...
Page 48: ...4 10 www geith com MAINTENANCE ...
Page 49: ...www geith com 5 1 SPECIFICATION SPECIFICATIONS Four Port Control Box ...
Page 52: ...5 4 www geith com SPECIFICATION ...
Page 57: ......