3-6
www.geith.com
OPERATION
Hydraulic Coupler With Four Port Control Box
AVOID SERIOUS INJURY OR DEATH
The following safety instructions are for your safety,
the safety of bystanders, and to prevent property
damage. Read the instructions before using the
machine and make sure you are familiar with all
safety messages and decals.
Hydraulic quick couplers must be installed, operated,
inspected, serviced, maintained and repaired by
properly trained and experienced people.
•
Do not operate the machine if there are other
workers or people in the work area. Also, never
allow people to stand or walk under the work tool
or attachment while operating.
•
Do not start or perform any work unless you are
properly trained. You should understand how to
use the quick coupler according to the
instructions.
•
Make sure that quick coupler is “FULLY
ENGAGED AND LOCKED” every time after you
change work tools or attachments.
•
Perform the recommended daily inspection and
maintenance for proper operation.
•
Attachments used with the machine should not
exceed the rated capacity and load limits of the
excavator.
Check for changes to load radius, maximum
operating capacity and read and follow load rating
charts before lifting loads or objects.
AVOID SERIOUS INJURY OR DEATH
Never use attachments or buckets which are not
approved by Geith. Buckets and attachments for safe
loads of specified densities are approved for each
model. Unapproved attachments can cause death or
serious injury.
Ensure the pin centers of the attachment to be used are
within the minimum and maximum range of the model
quick coupler being used (See Overall Dimensions on
Page 5-2). Attachments with pin centers greater than the
maximum range of the quick coupler will NOT be properly
retained.
Figure 13
NOTE: Position attachment on flat level surface.
Check that attachment is in the correct
orientation.
Enter the machine. Start the engine.
Extend the bucket cylinder fully to crowd the quick
coupler
Press the POWER button (1)
. An alarm will
sound and button will illuminate.
Press unlock button (2)
within six seconds of
pressing power button. Alarm will change tone and
unlock button will illuminate.
NOTE: Unlock button (2) [Figure 13] must be pressed
within six seconds of pressing power button
or system will not operate (alarm and lights
will shut-off). If this occurs, restart the
procedure by pressing the power button.
Crowd quick coupler to build pressure until locking clasp
(3) and sliding hook (4)
open.
WARNING
WARNING
1
3
4
2
Summary of Contents for QC100 H1
Page 1: ...GEITH QUICK COUPLER MANUAL www geith com PT No 823000088876 2 Released 05 2016 ...
Page 2: ......
Page 4: ......