4
Gerhard Geiger GmbH & Co. KG | 100W1552
1118
V000
en
EN
EN
5. Safety instructions for assembly
I
ATTENTION: Important safety instructions. Follow all installation
instructions, as incorrect installation can lead to serious injuries.
f
When mounting the motor without any mechanical protection of the driven parts and
of the tube which may become hot, the motor must be installed at a height of at least
2.5 m above the ground or of another level which provides access to the drive.
f
Before the motor is installed, all cables which are not needed are to be removed and
all equipment which is not needed for power-operated actuation is to be put out of
operation.
f
The actuating element of a manual release must be mounted at a height of less than
1.8 m.
f
If the motor is controlled by a switch or pushbutton, the switch or pushbutton must
be mounted within eyeshot of the motor. The switch or pushbutton must not be
located in the vicinity of moving parts. The height of installation must be at least
1.5 m above the floor.
f
Permanently installed control devices must be attached visibly.
f
In case of devices extending horizontally, a horizontal distance of at least 0.4 m must
be respected between the fully extended part and any other fixed element.
f
The rated speed and the rated torque of the motor must be compatible with the
device.
f
The mounting accessories that are used must be designed in accordance with the
selected rated torque.
f
Good technical knowledge and good mechanical skills are necessary for the motor
installation. Incorrect installation can lead to serious injury.
Electrical work must be carried out by a qualified electrician in accordance with the
regulations in force locally.
f
Only use connecting cables that are suitable with the environmental conditions and
which meet the construction requirements. (see accessories catalogue)
f
If the device is not equipped with a connecting cable and a plug, or other means for
disconnecting from the mains with a contact opening on each pole according to the
conditions of the overvoltage category III for full disconnection, a disconnecting
device of this type must be incorporated into the permanently installed electrical
installation according to the wiring rules.
f
Do not mount the connecting cables near hot surfaces.
f
A plug for the disconnection of the motor from the power supply must be accessible
after installation.
f
Damaged connecting cables must be replaced by Geiger connecting cables of the
same type.
f
The device must be mounted as described in the installation instructions. Fixations
shall not be made with adhesives since they are regarded as unreliable.