05.12 – FLOOR ARRAY
The Self Study command is used to detect the position of the cams that indicate the position of the floors in
the lift shaft. These positions are detected automatically by performing a series of movements. The following
positions are stored for each floor: A Low, B Low, A High, B High.
The values read in this phase are stored in the parameters contained in this menu.
No direct floor call or movement commands are possible (except jog and zero cycle) unless a Self Study
command has been correctly executed.
Position of cams floors 0 to 31
n
B Low
A High
Floor number
Position of lower edge
of cam B
Position of upper edge of
cam A
#
m
m
This allows to compensate the difference between the expected level for the car stop and the level that
the car really stop, when the car go from the bottom to the top.
This allows to compensate the difference between the expected level for the car stop and the level that
the car really stop, when the car go from the top to the bottom.
This parameter allows the selection of the floor where the edge of the cams will be set (by par. 11074
and 11076).
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.12.1 11048
Correction Fwd
m
FLOAT
0.0000
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.12.2 11050
Correction Rev
m
FLOAT
0.0000
RW
FVS
Menu
Par
Descrizione
UM
Tipo
FB BIT
Def
Min
Max
Acc
Mod
5.12.3 11066
Floor Selection
INT
0
0
31
RW
FVS
cam A
cam B
Line of the
floor
Positive direction
A High
B High
A Low
B Low