____________________ _
ADL300-EPCv2- User Guide
Page 42 of 64
05.07 – LIFT OUTPUTS
Lift control output signals are connected directly to the PAD parameters. See table in chapter 6.6 Outputs.
The set of lift output signals is comprised in two LiftStatusWords, see chapter 6.7.
Setting of the source for "lift status word 1":
0 Pad11
1 Pad12
Setting of the source for "lift status word 2":
0 Pad11
1 Pad12
Status word 1 is displayed as a hexadecimal value, see the description of "lift status word 1" for the
meaning of each bit
Status word 2 is displayed as a hexadecimal value, see the description of "lift status word 2" for the
meaning of each bit
05.08 – LIFT MONITOR
This menu contains some display parameters that are useful for verifying correct control functioning.
The calculation mode is displayed:
0
Direct mode
1
Mechanical data
The current speed reference value is displayed in m/s
The current speed reference value is displayed in rpm
The nominal torque value is displayed
The number of strokes performed by the control device is displayed
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.7.1 11450
Sel Status Word1
ENUM
0
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.7.2 11452
Sel Status Word2
ENUM
1
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.7.3 12030 Status Word 1
UINT32
500
R
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.7.4 12214 Status Word 2
UINT32
0
R
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.8.1 12010
Calculation Mode
INT16
0
R
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.8.2 12012
Actual spd reference
m/s
FLOAT
0.0000
R
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.8.3 12028
Actual spd reference
rpm
FLOAT
0.0000
R
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.8.4 12084
Rated Torque
Nm
FLOAT
-
-
-
R
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.8.5 12090
Trip Number
INT32
0.0000
R
FVS