ADL300-EPCv2- User Guide
Page 44 of 64
4
Fast Stop
5
Lift Stop
Setting of the behaviour of the drive if the "
Limit
" alarm is present. This alarm indicates that the rephaser
limits have been exceeded (upper/lower limit).
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast Stop
5
Lift Stop
Setting of the behaviour of the drive if the
Door Feedback
alarm is present. This alarm indicates that
feedback has not been received to confirm door opening.
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast Stop
5
Lift Stop
Setting of the behaviour of the drive if the
Contactor Feedback
alarm is present. This alarm indicates
that feedback has not been received to confirm contactor closing.
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast Stop
5
Lift Stop
Setting of the behaviour of the drive if the
Brake Feedback
alarm is present. This alarm indicates that
feedback has not been received to confirm brake opening/closing.
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast Stop
5
Lift Stop
Setting of the behaviour of the drive upon detecting the possible
Brake Feedback
alarm.
0
Ignore
1
Warning
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.9.3 11562
Lim Activity
INT16
1
0
5
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.9.4 11564
Door Activity
INT16
1
0
5
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.9.5 11566
Contactor Activity
INT16
1
0
5
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.9.6 11568
Brake Activity
INT16
1
0
5
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.9.7 11572
Brake run hold off
INT16
1
0
1
RW
FVS