____________________ _
ADL300-EPCv2- User Guide
Page 34 of 64
Self study
Self study command
Dig input 5X
Jog Fwd
Jog forward command
Dig input 7X
Jog Rev
Jog reverse command
Dig input 8X
Realignment
Realignment command
Dig input 9X
Forward
Forward command
Null
Reverse
Reverse command
Null
Stop
Stop command
Null
Maintenance
Maintenance command
Null
Battery Mode
Battery Mode command
Dig input 3X
Battery Run
Battery Run command
Dig input 3X
Floor 0
Floor command bit 0
Dig input 10X
Floor 1
Floor command bit 1
Dig input 11X
Floor 2
Floor command bit 2
Dig input 12X
Floor 3
Floor command bit 3
Null
0 = Up
1 = Down
2 = Autoselect
If the drive is in the emergency condition and cannot find zero, the parameter tells it which direction to move
in.
Setting of the source for the enable command “
COMMAND SOURCE LIST
”:
1110
Mon ing digitale E
1210
Mon ing digitale 1X
1212
Mon ing digitale 2X
1214
Mon ing digitale 3X
1216
Mon ing digitale 4X
1218
Mon ing digitale 5X
1220
Mon ing digitale 6X
1222
Mon ing digitale 7X
1224
Mon ing digitale 8X
1226
Mon ing digitale 9X
1228
Mon ing digitale 10X
1230
Mon ing digitale 11X
1232
Mon ing digitale 12X
16
Mon com contattore
19
Mon contatt discesa
17
Mon com freno
18
Mon porta aperta
3728
PAD15
6000
Zero
6002
One
20
Lift decom B0
21
Lift decom B1
22
Lift decom B2
23
Lift decom B3
24
Lift decom B4
25
Lift decom B5
26
Lift decom B6
27
Lift decom B7
28
Lift decom B8
29
Lift decom B9
30
Lift decom B10
31
Lift decom B11
32
Lift decom B12
33
Lift decom B13
34
Lift decom B14
35
Lift decom B15
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.5.1 11002
Emergency mode
ENUM
0
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.5.2 11400
Enable and sel
ENUM
1110
RW
FVS