Connect terminal block K11/K12 to the CHALLENGER 18-FMO terminals K4 and K9. The
maximum length of cable allowed is 5 metres.
CHALLENGER
KB/-KMU or MTD
CHALLENGER
-FMO
CHALLENGER M CHALLENGER TB
Preferred
cable-No.
Terminal-
Block K11
Terminal-
Block K12
Terminal-
Block K4
Terminal-
Block K9
cable
cable
1 1 - 1
- -
-
2 2 - 2
- -
-
3 3 - 3
- -
-
4 4 - 4
- -
-
5 5 - 5
- -
-
6 6 - 6
- -
-
7 7 - 7
- -
-
8 8 - 8
- -
-
9 9 - 9
- -
-
10 10 - 10 - -
-
11 - - -
brown red
12 - - - white blue
13 - - -
yellow green
14 - - -
green white
15 - - - -
-
16 - - - -
-
11 17 - - 7 -
-
13 18 - - 3 -
-
12 - 1 - 6 -
-
14 - 2 - 5 -
-
15 - 3 - 4 -
-
Connect the data cable (twisted pair) directly to the TCV2 or to the 10 pole Phoenix socket of
the rack provided.
Preferred
cable-color
10 pole socket 19“
rack
or connector
pins
ST10 TCV2
To the CHALLENGER
FMO terminal block
K5
Core-
pair
white 1 28D 1 1a
brown 2 28Z
2 1b
white 3 30D 3 2a
green 4 30Z 4 2b
white 5 32D 5 3a
orange 6 32Z
6 3b
white 9 26D 9 4a
blue 10 26Z 10 4b
Screen 7 24Z 7
Screen
Screen
Screen 8
8
Screen
Make sure the screen maintains a sufficient safety/insulation distance.