5
MSPA-1-AS
If the GFCI trips, follow the troubleshooting flow chart below to identify the
source of the problem.
Is the
GFCI
properly
connected?
If the
GFCI is
still tripping,
disconnect
the power input
wires.
Is the
GFCI still
tripping?
Replace
the GFCI.
Replace
the board.
The cable
is defective.
Call an
electrician!
Replace
the
transformer.
Reconnect
one component
at a time
until the
GFCI starts
tripping.
Replace
the defective
component.
Verify the
GFCI wiring
diagram &
reconnect it.
yes
yes
no
no
yes
no
Disconnect all
outputs,
including the
two wires of the
heater & the
light cord.
Is the GFCI still
tripping?
POWER & GROUND CHECK
GFCI Flow Chart