Service manual
28
1• On the power supply terminal block,
measure the voltage between
Line 1 (L1) and neutral.
You should read
≈
230 VAC.
Note:
If necessary, refer to the supplied
wiring diagram!
If the equipment is connected but nothing seems to work, the power
supply must be defective. Refer to the "Power & Ground Check" section of
this manual. If required, proceed as follows:
3• If you do not get good readings,
the electrical wiring must be
defective.
Call an electrician!
2• Measure the voltage between
Line 2 (L2) and neutral.
You should read
≈
230 VAC.
TROUBLESHOOTING