Service manual
16
ERROR MESSAGES
"FLC" Error Message
The "FLC" error message is displayed when a problem is detected with the
pressure switch. The system detects pressure while the pump is not
running.
2• If the "FLO" message does not
appear, remove the plastic cover
and replace the pressure switch
cable.
3• If the problem persists, replace
the board referring to the "How
to Replace the Board" section of
this manual.
1• Disconnect the pressure switch.
If the "FLO" message appears when
the pump is started, adjust the
pressure switch in the case of a recent
installation.
If this is not possible, replace the
switch.
(Refer to the respective section of this
manual).
For systems manufactured before 1998, the "FLC" message remains displayed until any key is
pressed. Press a key after each step to reset the system.
Power can remain on when the following steps are performed.