If the blower does not work, follow the troubleshooting flow chart below to
identify the source of the problem.
Is the "Blower" marker
displayed when you press
the respective key?
Do you read
≈
230 VAC to the
blower terminals
on the board?
Replace
the
blower
fuse (F7).
Replace
the top
side control.
It may be that the
blower does not
have enough
air entry.
Create an opening
to let more air
reach the blower.
Replace
the board.
Replace
the board.
Replace
the
blower.
yes
yes
no
no
Does the blower
restart after a few
minutes of cooling
down?
yes
no
TROUBLESHOOTING
Blower Flow Chart