![Gecko MSPA-1-AS Service Manual Download Page 46](http://html1.mh-extra.com/html/gecko/mspa-1-as/mspa-1-as_service-manual_573397046.webp)
45
MSPA-1-AS
Did you try
to replace the
spa light bulb?
Do you read
≈
12 VAC
to the light terminals
on the board
when the light is
at high intensity
(marker non-blinking)?
Replace
the spa light
fuse (F1).
Replace the board.
Replace
the spa
light socket.
Is the "Light"
marker displayed
when you press
the respective key?
Replace
the top side
control.
Replace
the board.
Replace
the light
bulb.
Does the
problem
persist?
yes
yes
no
yes
no
no
yes
no
If the spa light does not work, follow the troubleshooting flow chart below to
identify the source of the problem.
TROUBLESHOOTING
Spa Light Flow Chart