10
in.clear user manual
Maintenance Mode
Maintenance Mode keeps the bromine bank levels at
a stable and acceptable range when the spa is not being
used. Maintenance mode is the “everyday” mode
and is automatically ON when the system is activated.
Maintenance level adjustment changes the rate at which
bromine will be released into the spa water.
Finding and setting the right maintenance level will
keep the residual bromine level between 3 and 5 PPM
(the recommended range) when the spa is not being
used or is left unused for an extended period of time.
Once the proper maintenance level is determined,
keep the same setting unless the spa conditions change
(change in water temperature, spa location etc).
Finding the right bromine generation level is a crucial
step for the in.clear system to be stable and effective
(see Set Maintenance Mode).
With the stand alone version, the spa filtration should
be set to a minimum of 8 hours per day. To check the
minimum filtration time for your spa, see the Program
Key section.
With the linked version, it is not necessary to set
the filtration duration, as communication between
the pack and in.clear allows the system to stop and
start the associated pump at the best times.
It is important to note that the in.clear system can
ONLY generate bromine when the water is circulating.
If you are having problems maintaining a stable level
of bromine, or determining the proper maintenance
level for your spa, you may have to increase the daily
filtering time. Longer filtration produces a more steady
level of bromine.
Boost Mode
The Boost Mode should be activated every time you use
your spa. Boost mode increases the bromine generation
rate to attack pollutants in the water and helps rebuild
the necessary residual bromine in the water after each
use of the spa. Pollutants are introduced to the water
by the bathers, causing the bromine levels to decrease.
Activating the boost mode when you enter the spa will
prevent inadequate bromine levels and will restore your
bromine to the proper residual level.
Finding the right boost level is another crucial step for
the in.clear system to be stable and effective.
If water quality is not good after use, only the boost
level should be adjusted, not the maintenance level.
Keypad functions
On/Off &
Boost key
Maintenance
Diagnostic key
Down key
Up key
Bromine
Generation
Indicator
lo
hi
BromiCharge gauge
This manual details the functions of the in.clear with the default keypad (in.k200). If your spa pack uses a compatible
keypad (ex. in.k800) please see its manual for more specific information.
in.clear operating modes