Gecko Aeware 3 in.clear User Instructions And Functions Download Page 8

15

14

in.k450

in.k450

Filter cycle frequency

Press 

Prog

. key a fourth time.

The display will show 

FFxx

, with 

"xx" representing the number of 

filter cycles per day (up to 4).

Use 

Up 

or 

Down

 key to  

change setting.

Setting temperature unit

Water temperature can be 

displayed in either Fahrenheit 

(

˚F

) or Celsius (

˚C

). Press 

Prog

key a fifth time. The display will 

show either ˚F or ˚C.

Use

 Up 

or 

Down

 key to  

change setting.

Press

 Prog. 

key

 

once more to go 

back to normal mode.

Note: "

F

" will be displayed in 

in.ye Spa Packs.

Smart Winter Mode 

Our Smart Winter Mode 

protects your system from 

the cold by turning pumps on 

several times a day to prevent 

water from freezing in pipes.

When temperatures around 

pack drop to near freezing, the 

system will enter Smart Winter 

Mode. The pack will cycle 

through all pumps on high for 

1 minute to prevent water from 

freezing in the lines.

Water temperature regulation

In a regulation cycle, the system 

first generates water flow 

through the heater housing 

and the plumbing, in order 

to ensure accurate water 

temperature readings as well as 

avoiding heater activation in dry 

conditions.

After verifying pump activation 

and taking a water temperature 

reading if required, the system 

automatically turns the heater 

on to reach and maintain water 

temperature at Set Point. 

Cooldown

After heating the spa water to 

the desired Set Point, the 

heater is turned off, but its 

associated pump (Pump 1 

Low-speed or CP) remains on 

for a predetermined period of 

time to ensure adequate 

cooling of the heating element, 

this prolongs its useful life.  

The heater icon flashes during 

this time.

functions and user instructions

functions and user instructions

Setting the time

Enter Programming mode by 

holding 

Prog.

 key pressed down 

for 3 sec. The display will show 

the current time setting.

Setting the hour:

 Use 

Up 

or 

Down 

arrows to change hour 

setting

 (AM/PM)

.

Setting the minutes:

 Press 

Prog

key a second time.

Use 

Up 

or 

Down 

key to change 

hour setting.

Setting filter cycle start time

 

To program the filter cycle, you 

must enter these parameters: 

the start time and frequency. 

During a filter cycle, pumps run 

for one minute to purge the 

plumbing, then Pump 1 runs 

for the programmed number 

of hours. 

Press 

Prog

. key a third time. 

The display will show 

FSxx

, with 

"xx" representing the starting 

hour. 

Use 

Up 

or 

Down 

key to  

change setting.

Program key

Use 

Light

 key to display time 

or enter Programming menu 

by pressing and holding key. In 

Programming mode,  

the following parameters can 

be set: time, filter cycle start 

time, filter cycle frequency, and 

temperature unit.

Summary of Contents for Aeware 3 in.clear

Page 1: ...in ye spa pack general operation pages 2 7 in k450 keypad operation pages 9 15 in clear water sanitation system operation pages 16 43 in stream sound system operation pages 44 47...

Page 2: ...IN THIS UNIT TO PREVENT ELECTRIC SHOCK HAZARD AND OR WATER DAMAGE TO THIS CONTROL ALL UNUSED RECEPTACLES MUST HAVE A DUMMY PLUG THIS CONTROLLER MUST NOT BE INSTALLED IN PROXIMITY OF HIGHLY FLAMMABLE M...

Page 3: ...LECTRICAL CODE IN EFFECT AT THE TIME OF THE INSTALLATION Electrical wiring North American model Lamp test All the segments and LEDs are lighting up Software revision Revision of the software Low level...

Page 4: ...d to ensure proper functioning of the system Both the error code and the water temperature are alternatively displayed Allerrorscodeswillbedisplayed onthe keypad display FLO The system did not detect...

Page 5: ...9 in k450 overview in k450 user instructions and functions...

Page 6: ...element is cooling down or 3 not enough current available to start heater Light icon The Light icon lights up when the light is on The icon s number of rays is proportional to the light s intensity Sm...

Page 7: ...ON Third press Pump 3 OFF Blower ON Fourth press Pump 3 OFF Blower OFF A built in timer automatically turns blower off after a 20 minute period unless blower has been manually deactivated first functi...

Page 8: ...emperature reading if required the system automatically turns the heater on to reach and maintain water temperature at Set Point Cooldown Afterheatingthe spawaterto the desired Set Point the heaterist...

Page 9: ...17 16 in clear in clear brominebasedwatersanitationsystem user instructions and functions instruction video www gecko com inclear...

Page 10: ...rs should always shower before entering a spa warnings Warnings Important safety instructions For Canada in clear must only be used with Sodium Bromide such as BromiCharge scheduled or registered unde...

Page 11: ...de The primary function of the Maintenance Mode is to keep the bromine bank levels at a stable and acceptable range when the spa is not being used Maintenance Mode is the everyday mode and is automati...

Page 12: ...he plumbing even if the spa is brand new in clear getting started 3 Adjusting water chemistry in the spa Proper chemical maintenance of a spa is essential for the health of bathers Maintaining the qua...

Page 13: ...until you are able to stabilize your bromine level between 3 and 5 PPM Do NOT increase decrease maintenance level in steps greater than 2 Setting the maintenance level to a value that s too high can c...

Page 14: ...e 8 possible levels available with the Boost Mode As a rule of thumb the Boost level corresponds to the number of bathers using the spa Set the Boost level by using the up and down arrow to select the...

Page 15: ...miCharge to the water See details next page Never adjust the main tenance level of your in clear without allowing at least 24 hours following the end of the Boost period Boost cycles allow the residua...

Page 16: ...il the gauge reaches the green zone to clear a Low BromiCharge Warning Lo If after adding BromiCharge the Low BromiCharge Warning Lo or Low BromiCharge Error Err still occurs it could be the result of...

Page 17: ...irculating properly to the cell Make sure water chemistry is in balance refer to section 3 Adjusting water chemistry in the spa for more details Test your spa water for phosphate to make sure there is...

Page 18: ...substances contained in a liquid which are present in a molecular ionized or micro granular colloidal sol suspended form pH pH potential hydrogen is a measure of the acidity or basicity of a solution...

Page 19: ...r muriatic acid Install the rubber washer and the plastic nut on the threaded end of the cell Tighten plastic nut firmly Place the cell vertically with the cap end down into a plastic 19 liters 5 U S...

Page 20: ...m Hardness CaCo 125 to 200 adjust if necessary Alkalinity 80 to 90 adjust if necessary pH 7 0 to 7 8 adjust if necessary Adjust the above factors to meet optimum range values user guide for BromiCharg...

Page 21: ...GENERATOR on to build the bromine bank and bring it within 2 5 PPM range THE RECOMMENDED BROMINE LEVEL IS BETWEEN 2 5 PPM user guide for BromiCharge user guide for BromiCharge DIRECTIONS FOR USE For S...

Page 22: ...PM Purchasing a TDS meter at any spa pool store can do this or they will check it for you If you are adding water often beyond what has evaporated or splashed out then you may have a leak If you have...

Page 23: ...t work when AUX is selected as the source Turning power on off When connected to a power source the unit will automatically be ON Pressing and holding the Play Pause button will turn the unit off Once...

Page 24: ...g 2 In these settings turn Bluetooth on if it is not already 3 Choose Gecko in stream from the list of available devices 4 When prompted enter 5555 as the password Your device should now be paired wit...

Page 25: ......