![Gecko Aeware 3 in.clear User Instructions And Functions Download Page 15](http://html1.mh-extra.com/html/gecko/aeware-3-in-clear/aeware-3-in-clear_user-instructions-and-functions_573386015.webp)
29
28
in.clear
in.clear
keypad operations
+ / -
Keys
Maintenance level adjustment
changes the rate at which
bromine will be released into
the spa water. The bromine
generation rate ranges from 1 to
50, where 1 corresponds to the
system’s minimum generating
rate and 50 corresponds to
the maximum generation rate
allowed by the system.
Changing the water
temperature setpoint of your
spa, or using the economy
mode, could require a change
in the maintenance level of
your in.clear™. Lower water
temperatures may require a
lower maintenance level than
higher temperature setpoints.
Please check your bromine
level when changing your
temperature setpoint or using
the economy mode of your spa.
Maintenance Adjustment
Press and hold the Prog key
for 2 seconds to enter
Maintenance level adjustment
mode
Use the +/- keys
to adjust
maintenance level
Press the Prog key again to
enter Diagnostic Mode. This
mode may be used to monitor the
BromiCharge™ level of your spa
and may be a useful tool to use
when adding BromiCharge™ to
the water. See details next page.
Never adjust the main-
tenance level of your in.clear™
without allowing at least 24
hours following the end of the
Boost period. Boost cycles
allow the residual bromine
level to stabilize. Bromine levels
outside the 3-5 PPM range may
result from pollutants following
usage.
keypad operations
Diagnostic Mode
The primary function of
this mode is to indicate the
approximate BromiCharge™
level of your spa. This is a
useful tool when adding
BromiCharge™ to the water.
Press and hold the Prog Key
for 2 seconds, then press a 2nd
time to enter Diagnostic Mode.
An animation will be displayed
and within 10 seconds a nume-
rical value will be displayed.
The BromiCharge™ Gauge will
indicate the level of sodium
bromide in the spa water.
Diagnostic Mode can be
used to periodically adjust
BromiCharge™ level or to
check BromiCharge™ keypad
warnings and errors.
Press the Prog key to exit
Diagnostic Mode or the system
will automatically exit after
15 minutes.
Diagnostic mode and
BromiCharge™ Level Monitoring
are tools to help spa owners
maintain proper BromiCharge™
levels but do not replace the
need to perform water TDS
checks periodically at a local spa
dealer.