•The cell is installed after the heater in the circulation pump line.

• The appliance must be installed in a location that is inaccessible 

to a person in the bath or spa and must be located or fixed so 

that it cannot fall into the bath or spa. 

• The appliance is not intended for submersion but may be 

installed within the spa zone. 

• A means for disconnection must be incorporated in the fixed 

wiring in accordance with the wiring rules. 

• To reduce the risk of injury, do not allow children to operate  

this device.

• It is the responsibility of the user to test the spa water regularly 

to ensure that adequate amounts of bromine are generated to 

achieve proper sanitizer levels.

• Heavy spa usage may require higher bromine output to maintain 

proper free available bromine residuals.

• Maintaining overly high Sodium Bromide and bromine levels 

above recommended range can contribute to corrosion of spa 

equipment and may damage components of the spa.

• Do NOT use any ozone or UV sanitizer.

Warnings!

Important safety instructions

• Check the expiry date of the test kit as test results may be 

inaccurate if used after that date.

• Follow all aspects of the local and National Electrical Code(s) 

when installing the in.clear™ Automatic Bromine Generator.

• People with a medical condition should consult a physician 

before entering spa water.

•  Women who are pregnant should NOT enter the spa. 

• Maximum spa water usage temperature is 40°C. Bathing in spa 

water at 40°C should not exceed 15 minutes.

• For proper sanitation, Spas must be completely drained 

periodically. The number of days between COMPLETE SPA 

DRAINAGE is equal to the volume of the Spas water in liters, 

divided by 10 times the maximum number of daily spa users. 

Refill spa with water and repeat DIRECTION FOR USE of the 

device.

 

  - For a 1500 liters (400 US gallons) spa used by 2 adults twice a 

week: 1500 / (10 x (4/7)) = 262 days or 8 months

• In.clear™ is meant for a covered spa NOT swimming pools. 

• Users should always shower before entering a spa.

warnings

Warnings!

Important safety instructions

• For Canada, in.clear™ must only be used with Sodium Bromide 

(such as BromiCharge™) scheduled or registered under the Pest 

Control Product Act. For USA, the Sodium Bromide (such as 

BromiCharge™) must be registered under EPA.

• Read and follow this manual carefully and make sure to save it  

for later. 

• This manual contains important information on in.clear's 

installation, use and safety recommendations. It is your 

responsibility to install and use your in.clear™ unit safely.

• In.clear™ must be connected to a circuit protected by a ground  

fault interrupter device (GFCI) in North America or residual 

current device (RCD)  having a rated residual operating current 

not exceeding 30 mA in Europe.

• Make sure all electrical power is off before installing the in.clear™ 

unit. If the supply cord is damaged, it must be replaced by the 

manufacturer, its service agent or similarly qualified persons in 

order to avoid a hazard.

• Use only an electrical cord in good conditions to power 

in.clear™.

• Always clean or replace your filter cartridges at regular intervals, 

otherwise part of the bromine generated by in.clear™ will only 

serve to oxidize the dirt accumulated in the filter.

• Do NOT add any other sanitation chemicals in the spa other than 

registered Sodium Bromide (such as BromiCharge™)

• Operating the in.clear™ at reduced Sodium Bromide (such as 

BromiCharge™) levels will shorten the life of the cell.

• Do not open the in.clear™ unit; there are no serviceable parts 

inside.

• Disposal of the product: the in.clear™ unit must be disposed  

of separately in accordance with the local waste disposal  

legislation in force.

• This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, 

or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appliance 

by a person responsible for their safety.

• To reduce the risk of injury, do not allow children to operate this 

device.

• In.clear™ may not be suitable for in ground spas, it may affect 

some materials used in their construction.

warnings

Summary of Contents for Aeware 3 in.clear

Page 1: ...in ye spa pack general operation pages 2 7 in k450 keypad operation pages 9 15 in clear water sanitation system operation pages 16 43 in stream sound system operation pages 44 47...

Page 2: ...IN THIS UNIT TO PREVENT ELECTRIC SHOCK HAZARD AND OR WATER DAMAGE TO THIS CONTROL ALL UNUSED RECEPTACLES MUST HAVE A DUMMY PLUG THIS CONTROLLER MUST NOT BE INSTALLED IN PROXIMITY OF HIGHLY FLAMMABLE M...

Page 3: ...LECTRICAL CODE IN EFFECT AT THE TIME OF THE INSTALLATION Electrical wiring North American model Lamp test All the segments and LEDs are lighting up Software revision Revision of the software Low level...

Page 4: ...d to ensure proper functioning of the system Both the error code and the water temperature are alternatively displayed Allerrorscodeswillbedisplayed onthe keypad display FLO The system did not detect...

Page 5: ...9 in k450 overview in k450 user instructions and functions...

Page 6: ...element is cooling down or 3 not enough current available to start heater Light icon The Light icon lights up when the light is on The icon s number of rays is proportional to the light s intensity Sm...

Page 7: ...ON Third press Pump 3 OFF Blower ON Fourth press Pump 3 OFF Blower OFF A built in timer automatically turns blower off after a 20 minute period unless blower has been manually deactivated first functi...

Page 8: ...emperature reading if required the system automatically turns the heater on to reach and maintain water temperature at Set Point Cooldown Afterheatingthe spawaterto the desired Set Point the heaterist...

Page 9: ...17 16 in clear in clear brominebasedwatersanitationsystem user instructions and functions instruction video www gecko com inclear...

Page 10: ...rs should always shower before entering a spa warnings Warnings Important safety instructions For Canada in clear must only be used with Sodium Bromide such as BromiCharge scheduled or registered unde...

Page 11: ...de The primary function of the Maintenance Mode is to keep the bromine bank levels at a stable and acceptable range when the spa is not being used Maintenance Mode is the everyday mode and is automati...

Page 12: ...he plumbing even if the spa is brand new in clear getting started 3 Adjusting water chemistry in the spa Proper chemical maintenance of a spa is essential for the health of bathers Maintaining the qua...

Page 13: ...until you are able to stabilize your bromine level between 3 and 5 PPM Do NOT increase decrease maintenance level in steps greater than 2 Setting the maintenance level to a value that s too high can c...

Page 14: ...e 8 possible levels available with the Boost Mode As a rule of thumb the Boost level corresponds to the number of bathers using the spa Set the Boost level by using the up and down arrow to select the...

Page 15: ...miCharge to the water See details next page Never adjust the main tenance level of your in clear without allowing at least 24 hours following the end of the Boost period Boost cycles allow the residua...

Page 16: ...il the gauge reaches the green zone to clear a Low BromiCharge Warning Lo If after adding BromiCharge the Low BromiCharge Warning Lo or Low BromiCharge Error Err still occurs it could be the result of...

Page 17: ...irculating properly to the cell Make sure water chemistry is in balance refer to section 3 Adjusting water chemistry in the spa for more details Test your spa water for phosphate to make sure there is...

Page 18: ...substances contained in a liquid which are present in a molecular ionized or micro granular colloidal sol suspended form pH pH potential hydrogen is a measure of the acidity or basicity of a solution...

Page 19: ...r muriatic acid Install the rubber washer and the plastic nut on the threaded end of the cell Tighten plastic nut firmly Place the cell vertically with the cap end down into a plastic 19 liters 5 U S...

Page 20: ...m Hardness CaCo 125 to 200 adjust if necessary Alkalinity 80 to 90 adjust if necessary pH 7 0 to 7 8 adjust if necessary Adjust the above factors to meet optimum range values user guide for BromiCharg...

Page 21: ...GENERATOR on to build the bromine bank and bring it within 2 5 PPM range THE RECOMMENDED BROMINE LEVEL IS BETWEEN 2 5 PPM user guide for BromiCharge user guide for BromiCharge DIRECTIONS FOR USE For S...

Page 22: ...PM Purchasing a TDS meter at any spa pool store can do this or they will check it for you If you are adding water often beyond what has evaporated or splashed out then you may have a leak If you have...

Page 23: ...t work when AUX is selected as the source Turning power on off When connected to a power source the unit will automatically be ON Pressing and holding the Play Pause button will turn the unit off Once...

Page 24: ...g 2 In these settings turn Bluetooth on if it is not already 3 Choose Gecko in stream from the list of available devices 4 When prompted enter 5555 as the password Your device should now be paired wit...

Page 25: ......

Reviews: