cell cleaning

cell cleaning

Cell cleaning:

In.clear™ includes a self-cleaning feature to prevent scale deposits 

on the graphite electrodes of the in.clear™ system. However, 

deposits may still form due to hard water. If that happens the cell 

should be cleaned in an acidic solution.

To clean the in.clear

 cell, follow these steps:

 

All power must be disconnected before any service 

procedure is  

 

performed. Disconnect the 

communication cable and power  

 

cable of the 

in.clear™ unit.

Refer to acid manufacturer's instructions.

Wear eye protection and rubber gloves during these 

operations. Splashing or spilling acid can cause severe

 

personal injuries and/or property damage.

 

 

Always work in a well-ventilated area.

 

Always add acid to the water, never add water to the acid.

 

Do not pour acid outside of the unit where

 

the connectors are located.

 

Never use Acetic acid to clean the cell, as this will cause

 

permanent damage to cell components and void the

 

warranty. 

• To remove scales from the cell, we recommend to use 

Phosphoric acid (non-diluted) as the preferred cleaning product. 

• Close the spa Flow Shut Off Valves. Unscrew both unions

  from the unit and remove the cell from the spa equipment

  compartment.

Phosphoric acid

or muriatic acid

• Install the rubber washer and the plastic nut on the threaded end 

of the cell. Tighten plastic nut firmly.

• Place the cell vertically with the cap end down into a plastic 19 

liters (5 U.S. gallon) bucket and carefully pour the acid solution 

into the cell until the 4 plates are covered (careful not to 

overflow). The acid solution will begin to produce bubbles to 

clean the electrodes. 

  A foaming action will follow, which is caused by the scale 

deposits being dissolved from the plates. If rigorous foaming 

action does not begin, the cell does not need to be cleaned. 

Rinse and reinstall the cell.

• Allow the electrodes to remain in the solution until the foaming 

has stopped. However, DO NOT leave in acid for more than 

fifteen minutes. Excessive acid cleaning will damage the 

electrolytic cell.

• Pour the acid solution back into the bucket and rinse the cell 

thoroughly with clean tap water. If deposits are still visible, repeat 

operation for fifteen minutes maximum (some acid may need to 

be added to the solution).

• Remove the plastic nut and washer from the cell and keep them 

for future cell cleaning.

• Rinse the in.clear™ with fresh water.

• Re-install the in.clear™ unit into spa system plumbing, tighten all 

connections by hand. Open the spa flow Shut Off Valves.

• Reconnect the keypad and power cable.

• Turn power on and start up the pump. Check the keypad to 

see that the bromine generation LED is on and resume normal 

operation. 

Summary of Contents for Aeware 3 in.clear

Page 1: ...in ye spa pack general operation pages 2 7 in k450 keypad operation pages 9 15 in clear water sanitation system operation pages 16 43 in stream sound system operation pages 44 47...

Page 2: ...IN THIS UNIT TO PREVENT ELECTRIC SHOCK HAZARD AND OR WATER DAMAGE TO THIS CONTROL ALL UNUSED RECEPTACLES MUST HAVE A DUMMY PLUG THIS CONTROLLER MUST NOT BE INSTALLED IN PROXIMITY OF HIGHLY FLAMMABLE M...

Page 3: ...LECTRICAL CODE IN EFFECT AT THE TIME OF THE INSTALLATION Electrical wiring North American model Lamp test All the segments and LEDs are lighting up Software revision Revision of the software Low level...

Page 4: ...d to ensure proper functioning of the system Both the error code and the water temperature are alternatively displayed Allerrorscodeswillbedisplayed onthe keypad display FLO The system did not detect...

Page 5: ...9 in k450 overview in k450 user instructions and functions...

Page 6: ...element is cooling down or 3 not enough current available to start heater Light icon The Light icon lights up when the light is on The icon s number of rays is proportional to the light s intensity Sm...

Page 7: ...ON Third press Pump 3 OFF Blower ON Fourth press Pump 3 OFF Blower OFF A built in timer automatically turns blower off after a 20 minute period unless blower has been manually deactivated first functi...

Page 8: ...emperature reading if required the system automatically turns the heater on to reach and maintain water temperature at Set Point Cooldown Afterheatingthe spawaterto the desired Set Point the heaterist...

Page 9: ...17 16 in clear in clear brominebasedwatersanitationsystem user instructions and functions instruction video www gecko com inclear...

Page 10: ...rs should always shower before entering a spa warnings Warnings Important safety instructions For Canada in clear must only be used with Sodium Bromide such as BromiCharge scheduled or registered unde...

Page 11: ...de The primary function of the Maintenance Mode is to keep the bromine bank levels at a stable and acceptable range when the spa is not being used Maintenance Mode is the everyday mode and is automati...

Page 12: ...he plumbing even if the spa is brand new in clear getting started 3 Adjusting water chemistry in the spa Proper chemical maintenance of a spa is essential for the health of bathers Maintaining the qua...

Page 13: ...until you are able to stabilize your bromine level between 3 and 5 PPM Do NOT increase decrease maintenance level in steps greater than 2 Setting the maintenance level to a value that s too high can c...

Page 14: ...e 8 possible levels available with the Boost Mode As a rule of thumb the Boost level corresponds to the number of bathers using the spa Set the Boost level by using the up and down arrow to select the...

Page 15: ...miCharge to the water See details next page Never adjust the main tenance level of your in clear without allowing at least 24 hours following the end of the Boost period Boost cycles allow the residua...

Page 16: ...il the gauge reaches the green zone to clear a Low BromiCharge Warning Lo If after adding BromiCharge the Low BromiCharge Warning Lo or Low BromiCharge Error Err still occurs it could be the result of...

Page 17: ...irculating properly to the cell Make sure water chemistry is in balance refer to section 3 Adjusting water chemistry in the spa for more details Test your spa water for phosphate to make sure there is...

Page 18: ...substances contained in a liquid which are present in a molecular ionized or micro granular colloidal sol suspended form pH pH potential hydrogen is a measure of the acidity or basicity of a solution...

Page 19: ...r muriatic acid Install the rubber washer and the plastic nut on the threaded end of the cell Tighten plastic nut firmly Place the cell vertically with the cap end down into a plastic 19 liters 5 U S...

Page 20: ...m Hardness CaCo 125 to 200 adjust if necessary Alkalinity 80 to 90 adjust if necessary pH 7 0 to 7 8 adjust if necessary Adjust the above factors to meet optimum range values user guide for BromiCharg...

Page 21: ...GENERATOR on to build the bromine bank and bring it within 2 5 PPM range THE RECOMMENDED BROMINE LEVEL IS BETWEEN 2 5 PPM user guide for BromiCharge user guide for BromiCharge DIRECTIONS FOR USE For S...

Page 22: ...PM Purchasing a TDS meter at any spa pool store can do this or they will check it for you If you are adding water often beyond what has evaporated or splashed out then you may have a leak If you have...

Page 23: ...t work when AUX is selected as the source Turning power on off When connected to a power source the unit will automatically be ON Pressing and holding the Play Pause button will turn the unit off Once...

Page 24: ...g 2 In these settings turn Bluetooth on if it is not already 3 Choose Gecko in stream from the list of available devices 4 When prompted enter 5555 as the password Your device should now be paired wit...

Page 25: ......

Reviews: