Gecko Aeware 3 in.clear User Instructions And Functions Download Page 14

27

26

in.clear

in.clear

in.clear 

keypad operations

Keypad functions

On/Off & Boost 

key

Maintenance

Diagnostic 

key

Down key

Up key

Bromine 

generator

ON indicator

lo

hi

BromiCharge™ gauge

keypad operations

Boost key

The first press of the Boost 

key     turns the in.clear™ 

ON and puts the in.clear™ 

into maintenance mode. ON 

appears on the keypad display.

Press and hold the Boost 

key    for 2 seconds to turn 

in.clear™ OFF. OFF will appear 

on the keypad display.

With the system in 

Maintenance Mode, press the 

Boost key     to activate the 

Boost Mode.  

Note: The Boost mode should 

be activated every time you use 

your spa.

The keypad display will show a 

numeric value that corresponds 

to the selected level. There are 

8 possible levels available with 

the Boost Mode.

As a rule of thumb, the Boost 

level corresponds to the 

number of bathers using the 

spa.

Set the Boost level by using the 

up and down arrow 

 to 

select the number of bathers 

that use the spa (i.e., husband 

and wife = 2, and so on).

Confirm the selection by 

pressing the Boost key     again 

or wait 5 seconds for the system 

to save the desired level and 

activate the Boost Mode cycle.

Note: In.clear™ keeps your 

boost level in memory.

Press the Boost key     during 

a Boost cycle will cancel the 

remainder of that Boost cycle 

and return the in.clear™ system 

to maintenance mode.

The Bromine Generation 

Indicator (LED), located above 

the Boost key, lights up when 

the cell is producing bromine 

and is OFF when no bromine is 

being produced.

Note: The Bromine Generation 

Indicator will blink if the 

in.clear™ system cannot 

generate bromine due to low or 

no water flow.

Summary of Contents for Aeware 3 in.clear

Page 1: ...in ye spa pack general operation pages 2 7 in k450 keypad operation pages 9 15 in clear water sanitation system operation pages 16 43 in stream sound system operation pages 44 47...

Page 2: ...IN THIS UNIT TO PREVENT ELECTRIC SHOCK HAZARD AND OR WATER DAMAGE TO THIS CONTROL ALL UNUSED RECEPTACLES MUST HAVE A DUMMY PLUG THIS CONTROLLER MUST NOT BE INSTALLED IN PROXIMITY OF HIGHLY FLAMMABLE M...

Page 3: ...LECTRICAL CODE IN EFFECT AT THE TIME OF THE INSTALLATION Electrical wiring North American model Lamp test All the segments and LEDs are lighting up Software revision Revision of the software Low level...

Page 4: ...d to ensure proper functioning of the system Both the error code and the water temperature are alternatively displayed Allerrorscodeswillbedisplayed onthe keypad display FLO The system did not detect...

Page 5: ...9 in k450 overview in k450 user instructions and functions...

Page 6: ...element is cooling down or 3 not enough current available to start heater Light icon The Light icon lights up when the light is on The icon s number of rays is proportional to the light s intensity Sm...

Page 7: ...ON Third press Pump 3 OFF Blower ON Fourth press Pump 3 OFF Blower OFF A built in timer automatically turns blower off after a 20 minute period unless blower has been manually deactivated first functi...

Page 8: ...emperature reading if required the system automatically turns the heater on to reach and maintain water temperature at Set Point Cooldown Afterheatingthe spawaterto the desired Set Point the heaterist...

Page 9: ...17 16 in clear in clear brominebasedwatersanitationsystem user instructions and functions instruction video www gecko com inclear...

Page 10: ...rs should always shower before entering a spa warnings Warnings Important safety instructions For Canada in clear must only be used with Sodium Bromide such as BromiCharge scheduled or registered unde...

Page 11: ...de The primary function of the Maintenance Mode is to keep the bromine bank levels at a stable and acceptable range when the spa is not being used Maintenance Mode is the everyday mode and is automati...

Page 12: ...he plumbing even if the spa is brand new in clear getting started 3 Adjusting water chemistry in the spa Proper chemical maintenance of a spa is essential for the health of bathers Maintaining the qua...

Page 13: ...until you are able to stabilize your bromine level between 3 and 5 PPM Do NOT increase decrease maintenance level in steps greater than 2 Setting the maintenance level to a value that s too high can c...

Page 14: ...e 8 possible levels available with the Boost Mode As a rule of thumb the Boost level corresponds to the number of bathers using the spa Set the Boost level by using the up and down arrow to select the...

Page 15: ...miCharge to the water See details next page Never adjust the main tenance level of your in clear without allowing at least 24 hours following the end of the Boost period Boost cycles allow the residua...

Page 16: ...il the gauge reaches the green zone to clear a Low BromiCharge Warning Lo If after adding BromiCharge the Low BromiCharge Warning Lo or Low BromiCharge Error Err still occurs it could be the result of...

Page 17: ...irculating properly to the cell Make sure water chemistry is in balance refer to section 3 Adjusting water chemistry in the spa for more details Test your spa water for phosphate to make sure there is...

Page 18: ...substances contained in a liquid which are present in a molecular ionized or micro granular colloidal sol suspended form pH pH potential hydrogen is a measure of the acidity or basicity of a solution...

Page 19: ...r muriatic acid Install the rubber washer and the plastic nut on the threaded end of the cell Tighten plastic nut firmly Place the cell vertically with the cap end down into a plastic 19 liters 5 U S...

Page 20: ...m Hardness CaCo 125 to 200 adjust if necessary Alkalinity 80 to 90 adjust if necessary pH 7 0 to 7 8 adjust if necessary Adjust the above factors to meet optimum range values user guide for BromiCharg...

Page 21: ...GENERATOR on to build the bromine bank and bring it within 2 5 PPM range THE RECOMMENDED BROMINE LEVEL IS BETWEEN 2 5 PPM user guide for BromiCharge user guide for BromiCharge DIRECTIONS FOR USE For S...

Page 22: ...PM Purchasing a TDS meter at any spa pool store can do this or they will check it for you If you are adding water often beyond what has evaporated or splashed out then you may have a leak If you have...

Page 23: ...t work when AUX is selected as the source Turning power on off When connected to a power source the unit will automatically be ON Pressing and holding the Play Pause button will turn the unit off Once...

Page 24: ...g 2 In these settings turn Bluetooth on if it is not already 3 Choose Gecko in stream from the list of available devices 4 When prompted enter 5555 as the password Your device should now be paired wit...

Page 25: ......

Reviews: