XB ROTARY TILLER ASSEMBLY
13
BEFORE PUTTING ROTARY
TILLER INTO SERVICE
IMPORTANT - INSTRUCTIONS PRIOR TO START UP
SHIPPED WITHOUT OIL IN GEARBOXES AND WITHOUT GREASE IN GREASE
FITTINGS. UNIT MUST BE SERVICED BEFORE USING.
Fill gearbox using gear oil (type SAE-EP-80W 90).
For all grease fittings use TYPE/grade II tube grease.
STEP 1:
Place rotary tiller so that the deck is secure
and level.
STEP 2:
Remove oil plug located at top of transmission
gearbox (
See Fig. A & B
).
STEP 3:
Fill gearbox using gear oil until gearbox is
approximately
1
/
2
full (16 oz). The plug has
marks on it. (
See Fig. C
) Make sure oil level
is close to top line, but not over it.
DO NOT OVERFILL!
Fig. A
Fig. B
Fig. C