Code/Type
TE20
L
2
S
X
S
Item in the order code
14
15
16
17
18
19
Explanation of the items in the order code
Item in the order code
Designation
Explanation
14
Feedback location
TE 20
Control top T.VIS E-20
15
Control top type
N
without solenoid valve
M
1 solenoid valve Y1 (retrofittable: Y2,
Y3)
N
2 solenoid valves Y1, Y2/ 2
Y1=main stroke
Y2=lifting of the valve disk
(retrofittable: Y3)
J
2 solenoid valves Y1, Y3
Y1=main stroke
Y3=lifting of the double-disk for the
external air connection of an air/air
actuator or an external process valve
(retrofittable: Y2)
L
3 solenoid valves Y1, Y2, Y3
16
Feedback
2
2 digital feedback signals
17
Type of interface/mode
S
Ex 12/24VDC-NAMUR
18
Solenoid valve
S
12VDC/EX
X
24VDC/EX
0
without
19
Screw connection
S
Air connection metric, M20x1.5/Ex
cable gland
N
Air connection imperial, M20x1.5/Ex
cable gland
Options
/18
Supply air throttle: regulates the
opening speed of the valves
/19
Exhaust air throttle: regulates the
closing speed of the valves
Technical data and operating conditions
Type plate
430BAL013985EN_6
36