Fig.47
10.3.2.4 Removing the sensor module
Fig.48
Carry out the following steps:
1.
Disconnect all cables from the connection terminals of the sensor module
(43).
2.
Unscrew and remove all screws (57) with washers (18).
3.
Remove the sensor module (43) from the base (5).
®
Sensor module is removed.
10.3.2.5 Removing the pneumatic block
Requirement:
•
If only O-rings (42) and (55) are to be changed, solenoid valves (63)/valve
plate (65) can remain on the pneumatic block (8).
Carry out the following steps:
1.
Undo the screws (57.1, 57.2).