7
VE1016
VE1016
VE1016AM
Zo
ne
X
1
2
3
4
5
6
7
GND +12V
Ala
rm
Ala
rm
Ta
m
pe
r
WT
Ta
mper
J3 J4
CP
Zo
ne
Y
+12V
Ta
mper
WT
Ta
mper
1
2
3
4
5
6
7
8
9
10
GND
Ala
rm
D/
N-Rtes
t
AM AM
Al
ar
m
Zon
e X
CP
Z
one Y
+12V
Ta
m
per
WT
Ta
mper
1
2
3
4 5
6
7
8
9
10
GN
D
Alarm
AM AM
Al
ar
m
Zo
n
e X
Z
one Y
+12V
Ta
m
p
er
WT
Ta
m
per
GN
D
Al
ar
m
AM AM
Alarm
Z
one X
+12V
Ta
m
pe
r
WT
Ta
mper
GN
D
Al
ar
m
D/
N
-Rt
es
t
AM AM
Alarm
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
CP
CP
Z
one X
1
2
3
4
5
6
7
GND +
12V
Al
arm
Al
arm
Ta
m
per
WT
Ta
mper
Z
o
ne X
GND +12V
Alarm
Alarm Ta
mper
WT
Ta
m
pe
r
GND +12V
Alarm
Alarm Ta
mper
WT
Ta
m
pe
r
GND +1
2V
Al
arm
Al
arm
Ta
m
per
WT
Ta
mper
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
CP
J3 J4
J3 J4
J3 J4
J3 J4
J3 J4
D/
N-R
te
st
J3 J4
J3 J4
J3 J4
J3 J4
VE1016AM
CP
1
2
Normal
larm
A
Tamper
Short
AM/TF
4.7 k
9.4
0
Ω
k
Ω
Ω
8
Normal
larm
A
Tamper
Short
4.7 k
9.4
0
Ω
k
Ω
Ω
8
Normal
larm
A
Tamper
Short
4.7 k
9.4
0
Ω
k
Ω
Ω
8
+1
2V
Ta
m
per
WT
Ta
mper
GND
Alarm
AM AM
Alar
m
D/
N-
R
tes
t
8
Normal
larm
A
Tamper
Short
AM/TF
4.7 k
9.4
0
Ω
k
Ω
Ω
8
8
D
/N-
Rt
es
t
EN: Installation Sheet
Introduction
The VE1016 series consists of models VE1016 and
VE1016AM. These detectors use PIR or PIR-AM sensors.
They have a patented mirror, pyro, and signal processing
technology.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability such as
(see Figure 1):
•
Direct sunlight on the detector
•
Strong draughts onto the detector
•
Heat sources within the detector field of view
•
Large animals within the detector field of view
•
Obscuring the detector field of view with large objects,
such as furniture
•
Objects within 50 cm (20 in.) of the anti-masking (AM)
detector
•
Installing two detectors facing each other and less than
50 cm (20 in.) apart
Installing the detector
Figure 7 legend
Item Description
1.
Standard connection (factory default)
2.
Dual loop connection
CP Control
panel
WT Walk
test
AM Antimasking
D/N Day/night
Rtest Remote
test
To install the detector:
1. Lift off the custom insert and remove the screw
(see Figure 2, item 1).
2. Using a screwdriver, carefully prise open the detector (see
Figure 2, items 2 and 3).
3. Fix the base to the wall between 1.8 m and 3.0 m (5.9 and
9.8 ft.) from the floor. For flat mounting use a minimum of
two screws (DIN 7998) in positions A. For corner-mounting
use screws in positions B or C (Figure 4). To install a pry-
off tamper, use position A or B.
4. Wire the detector (see Figures 4 and 7).
P/N 146278999-2 • REV 2.0 • ISS 20JUL10
3 / 20