![GE T17 Installation Manual Download Page 67](http://html.mh-extra.com/html/ge/t17/t17_installation-manual_127652067.webp)
Model T17 Installation Guide
59
Chapter 4. Inserting T17 Transducers into the Pipe
4.2.2 Mounting the Insertion Mechanism (cont.)
2.
Visually inspect the transducer to make sure the top Swagelok
®
1
fitting is not loose (see
below).
3.
Remove the four bolts that fasten the barrel to the packing gland.
Figure 68: Check Fitting and Remove Bolts
1.
Swagelok
®
is a registered trademark of the Swagelok Company.
CAUTION!
The stop ring at the end of the barrel is supposed to be loose.
DO NOT
tighten the
Swagelok
®
fitting or you could change the transducer alignment.
Swagelok
Top
Fitting
Stop Ring
Fastening Bolts