Model T17 Installation Guide
55
Chapter 3. Installing an Isolation Valve
Chapter 3. Installing an Isolation Valve
3.1
Introduction
If one has not already been installed, follow the instructions in this chapter to install an isolation valve on each
transducer nozzle for applications using the flare gas insertion mechanism. As the procedure is identical for all path
configurations and flange sizes, only one installation configuration is described here as an example.
3.2
Valve Installation for 3-inch Flanges
Refer to
below and install
3-inch ANSI flanged full-bore isolation valves
on both transducer nozzles with a
gasket, studs and nuts. Orient the valve handles to minimize interference. Note the following requirements:
•
150# RF flanges:
8 in. face-to-face distance, 5/8 in. diameter studs and nuts
•
300# RF flanges:
11.125 in. face-to-face distance, 3/4 in. diameter studs and nuts
Figure 66: Standard Isolation Valve Installation
2 PLACES; REF ONLY
3 INCH SCH 80 PIPE NOZZLE
3 INCH 150 LB, RF WELDING NECK FLANGE
2 PLACES; REF ONLY
FLOW
TRANSDUCER PORT
UPSTREAM
TRANSDUCER PORT
DOWNSTREAM
GASKET
GASKET