Chapter 2. Installing the Pipe Nozzles
2.4.2 Selecting and Marking the First Nozzle Location - MR2 Mid-Radius (cont.)
4.
Using the calculated or tabulated
AS/2
dimension for your installation, center punch the pipe to mark the
location for the center of the first nozzle (see
below).
Figure 51: Marking the First Nozzle Location
Table 7: AS/2 Values for Common Pipe Sizes with 0.375” Wall Thickness
Pipe OD
AS/2 Dimension
inches
mm
inches
mm
26
650
13.829
351.26
28
700
14.876
377.86
30
750
15.924
404.46
32
800
16.971
431.06
34
N/A
18.018
N/A
36
900
19.065
484.26
38
N/A
20.113
N/A
40
1000
21.160
537.46
42
1050
22.207
564.06
44
1100
23.254
590.66
46
N/A
24.301
N/A
48
1200
25.349
643.86
52
1300
27.443
697.06
54
N/A
28.490
N/A
56
1400
29.538
750.25
60
1500
31.632
803.45
64
1600
33.726
856.65
66
N/A
34.774
N/A
Top of Pipe
Reference
Point
Center Point
of 1st Nozzle
2
AS