0150-0295A
38
GE Security DVMRe StoreSafe Pro
Global Alarm Record Rate
[CANCEL] [OK]
% Time:
60 pps
40 days 20 h (Alarm)
15 days 11 h (Total)
1%
Estimate of the % of time the
unit will typically spend in
alarm mode. For example
if you expect to have about 5
total periods of alarms each day,
each lasting 3 minutes on average,
then the % of the time will be 1%.
(15 min/24 hours)
Record
Duration
Calculator
1. Rotate the
Jog
to navigate, and the
Shuttle
to change the values.
2. To save changes and exit the menu: Select [OK], and then press the Enter button.
3. To exit the menu without making changes: Press the Menu button, or select [CANCEL], then
press the Enter button.
q
Main Menu
→
Record
→
Alarm/Event Actions
Use this menu to specify how the unit will record during Alarm and Event actions.
Alarm/Event Actions
Pre Event Duration
Post Event Duration
Pre Alarm Duration
Alarm Record Mode
ACTIVITY Link to Event
5
0
0
Interleaved
Yes
[CANCEL] [OK]
Pre Event Duration:
The unit will record up to 5 seconds of data ahead of the event trigger, at the
Event Record Rate. Select from 0 to 5 seconds.
Post Event Duration:
The unit will record up to 250 seconds after the completion of the Event, at the
Event Record Rate. Select from 0 to 250 seconds.
Pre Alarm Duration:
The unit will record up to 5 seconds of data ahead of the alarm trigger, at the
Alarm Record Rate. Select from 0 to 5 seconds.
Alarm Record Mode:
Select from Interleaved or Exclusive.
ACTIVITY Link to Event:
Select from Yes or No.
Summary of Contents for StoreSafe Pro
Page 1: ...StoreSafe Pro ...
Page 83: ...0150 0295A ...